Default Settings of the DynaControl V6 LCD Controller

Language: English
Setting for Customer Access Code: "1111".
Standby temperature for all zones: 66C (150F) lower than programmed setpoints.
Hi/ lo limit deviation for all temperature zones: + 20C (36F).
Temperature zone offset: 0C (0F).
Setpoint limitation: 218C (425F).
Automatic sleep mode: Off.
Sequential heat-up: Off.
Power-On motor Stop: No.
Power-On heater start: Yes.
Global setpoints: No.
Minimum pump speed: 0 RPM).
Maximum pump speed: 90 RPM.
The ITW Dynatec factory default settings may be re-loaded in the controller per the instructions
given in Chapter 5: Zone Configuration (P1 parameter).
Controller Setup Page 4-9
Revised 10/14