Page 4-8 Controller Setup
Revised 10/14
System Values That Are Factory Programmed (not customer programmable)
Minimum setpoint value: 10C (50F).
Maximum setpoint value (setpoint limitation): 218C (425F).
Maximum alarm deviation: 50 (C or F).
Minimum alarm deviation: 5 (C or F).
Maximum standby temperature: 150 (C or F) less than setpoint.
Minimum standby temperature: 30 (C or F) less than setpoint.
"Actual" temperature indication range: 0C to 260C (32F to 500F).
Customer Programmable System Values Preset At The Factory
ITW Dynatec can set the controller's system values to customer's specs, if provided.
If customer's specs are not provided, the following values will be entered into the DynaControl con-
troller at the factory. They may be changed by reprogramming through the controller.
(These are not the "default" settings, see following section).
Language: Chinese (when shipment is to a China destination).
Standby: 82C (180F) under setpoint.
All other system values: controller defaults.