6A-3. Uneven Exposure Adjustment
I.
Exposure Lamp Position
1.
Remove the top cover and the exposure glass
(10 screws).
2.
Verify that the lamp is properly seated.
3 .
Move the scanner to the right.
4.
Open the by-pass feed table, the black inner
cover, and the toner cartridge holder.
5.
Remove the two cover plates (1 screw each).
6.
Through the sight holes in the reflector, con-
firm the lamp filament position (See figure).
7.
Correct the horizontal position by tightening
or loosening the two adjusting screws.
NOTE: The vertical adjustment is done in produc-
tion only.