PHENOMENON
Blurred or fuzzy image in
the center of copies.
10. Reinstall the drum and make 10 B4 copies.
powder). Then, operate the copier in free run mode for 2 or 3 minutes. (To
help the drum recover its photoconductive characteristics).
11. Make test copies.
cedure.
12. Seal the used cotton pads in a plastic bag and bring it back to the service
center for disposal.
NOTE: If the drum does not respond to cleaning, it has probably crystallized or is
simply worn out.
ACTION
If the problem persists, repeat the drum cleaning pro-
In such case, replace the drum.
(To pick-up any excess cleaning
1 0 - 2 3