6D-8. By-pass Feed Table Removal
1.
Open the front cover and remove the front
inner cover (4 screws). [FT3020]
Open the front cover, push the slide unit to the
left, and remove the inner cover (5 screws).
[FT3050/FT3060]
Remove the E-ring from the front shaft of the
2.
by-pass feed table.
3 .
Remove the right rear cover (2 screws)
4.
Open the by-pass feed table and remove the
inner cover and the toner tank cover (2
screws).
Remove the rear cover (2 screws) and the
5.
main PCB (2 screws, 4 connectors). [FT3020]
Remove the rear cover (2 screws) and the
o p t i c s P C B ( 1 s c r e w , 4 c o n n e c t o r s ) .
[FT3050/FT3060]
Remove the stud screw from the rear side.
6.
7.
Take off the by-pass feed table. [FT3020]
(1 connector, 1 bushing) [FT3050/FT3060]
CAUTION: When reinstalling, do not damage the
cassette arm release lever nor the by-
pass feed table sensor.