July 1, '85
N o .
Adjustment Item
11
Home Position
[FT3020]
12
Home Position
[FT3050/FT3060]
7-6
Adjustment Standard
Home Position Switch turns
on when the scanner
bracket is 24.5 mm (0.96")
from the outside of the left
optical frame.
Home Position Sensor
Bracket ;
108 ± 0.5 mm
(4.25" ± 0.02")
Distance
between
Second Scanner and the
Left Optical Frame :
35.5 ± 1 mm
(1.40"
±
0.04")
the
Note
35.5 ± 1 mm
(1.40" ± 0.04")