July 1, '85
PHENOMENON
ACTION
White copy
A totaly white copy may be the result of charge failure.
1. Check the charge corona unit contact.
2. Check the charge corona wire.
3. Check charge power pack input/output.
4. For the FT3050 and the FT3060, check the inner fuse of the main transformer.
5. Check the drum drive belt. (It may be off of the pulley.)
10-4