Ricoh FT3020 Field Service Manual page 52

Table of Contents

Advertisement

Oct. 1, '83
Reinstall the magnification change clamp.
8.
9.
Move the second scanner to the return posi-
tion.
10.
Working from the clamp, thread the long end
of the wire in the lower groove of the clamp
and run it under the inside track of the tension
pulley (WP1).
11.
Then run the wire under the outer track of the
second scanner pulley (WP2), through the
wire clamp below the screw, and around the
lower track of WP3.
12.
Run the wire around the lower track of WP4,
and then give it two and half (2.5) turns clock-
wise around the scanner drive pulley, winding
from lower to upper.
13.
Next, run the wire over the upper track of
WP4, the lower track of WP6, the inner track
of WP2, and the inner track of WP7.
14.
Guide the left end of the wire through the
upper groove of the magnification change
clamp; then pull the ends of the wire together
and join them with the wire hook.
6-10-b
15. Reassemble the copier.
16. Check and adjust the magnification (See 6G-
5) .