6B-8. Image Density Sensor Adjustment
[FT3050/FT3060]
CAUTION: Before adjusting the ID sensor after
new drum installation,
machine about 5 times in Free Run
mode to clean the setting powder from
the drum.
NOTE: It is better to use a plastic screw driver to
avoid possible drum damage.
* Adjustment Standard : +4 ± 0.2V
1.
Remove the rear cover (2 screws).
2.
Connect a multimeter to TPPSN (hot line) and
TPGND (ground line) on the main PCB.
Turn on DIP SW101 #6.
3.
4.
Open the front cover and turn on the main
switch.
5.
Adjust the VR on the front end of the ID sen-
sor PCB.
6 - 2 0
cycle
the