[*4]
Hose insertion depth: 70 mm
3
Radiator hose clamp:
10.8 – 11.8 Nm {1.1 – 1.2 kgm}
[*5]
a Install each hose so that it will not be twisted.
a When installing the air conditioner hoses, take
care that dirt, dust, water, etc. will not enter
them.
a When tightening each joint of the air condi-
tioner hose, check that O-ring (70) is fitted to it.
a Apply sufficient amount of compressor oil for
R134a [DENSO: ND-OIL8, ZEXEL: ZXL100PG
(equivalent to PAG46) ] to each O-ring.
3
Tightening torque for air conditioner refriger-
ant piping
Thread size
16 × 1.5
11.8 – 14.7 Nm {1.2 – 1.5 kgm}
22 × 1.5
19.6 – 24.5 Nm {2.0 – 2.5 kgm}
24 × 1.5
29.4 – 34.3 Nm {3.0 – 3.5 kgm}
Filling air conditioner circuit with refrigerant
q
(R134a)
Fill the air conditioner circuit with refrigerant
(R134a).
a Quantity: 1,330 ± 50 g
14
Tightening torque
50 Disassembly and assembly
Refilling with compressor oil
q
a If any air conditioner hose was replaced,
add compressor oil for R134a (DENSO:
ND-OIL8, ZEXEL: ZXL100PG (equivalent
to PAG46)) to the air conditioner compres-
sor by the following quantity. (If the com-
pressor oil is added too much, the cooling
performance lowers. Take care.)
5
Air conditioner compressor: Compressor
oil for R134a [DENSO: ND-OIL8, ZEXEL:
ZXL100PG (equivalent to PAG46) ]
: 45 ml
(After replacement of hose between
compressor and condenser)
: 30 ml
(After replacement of hose between
condenser and receiver drier)
: 21 ml
(After replacement of hose between
receiver drier and air conditioner unit)
: 80 ml
(After replacement of hose between
compressor and air conditioner unit)
a Since the compressor oil for R134a
absorbs moisture very easily, put the cap
on the oil container to shut off air immedi-
ately after supplying the oil.
a The compressor oil for R134a can dissolve
acrylic resin and polystyrene. Take care.
Refilling with oil
q
Add oil through the oil filler to the specified
level. Run the engine to circulate the oil
through the system. Then, check the oil level
again.
5
Hydraulic tank: 470 l
Refilling with coolant
q
Add coolant through the coolant filler to the
specified level. Run the engine to circulate the
coolant through the system. Then, check the
coolant level again.
5
Coolant: 100 l
Bleed air from the fuel system. For details, see
q
Testing and adjusting, "Bleeding air from fuel
circuit".