Komatsu Galeo PC800-8 Shop Manual page 416

Hydraulic excavator
Table of Contents

Advertisement

SEN00913-02
17. Function for Abnormality Record [02]
The machine monitor records failures that
occurred on the machines in the past after clas-
sifying them into failures in the electric system
and those in the mechanical system. Information
on them can be displayed through the following
operation.
1) Selection of menu
Select 02 Abnormality Record in the initial
display of Service Menu and depress [
switch.
2) Selection of Submenu
Select an appropriate item from Submenu in
the Abnormality Record selection display
and depress [
No.
Abnormality Record Submenu
Return
00
(termination of Abnormality Record)
01
Electrical Systems
02
Mechanical Systems
22
] switch.
3) Information shown in display of Abnormality
Record in the electrical system
[1]: The numerator expresses sequence of
failure occurrence, counting from the
latest one. The denominator expresses
the total number of a specific failure
recorded.
[2]: "E" is displayed as long as the failure is
not repaired.
[3]: Abnormality Code No. (section in 4 dig-
its and phenomenon in 2 digits)
]
[4]: Time elapsed since the occurrence of
the first failure
[5]: Contents of failure
a See the operator menu "Failure codes
table".
4) Information shown in display of Failure His-
tory in the mechanical systems
[1]: Record No.
[2]: Contents of Abnormality
[3]: Abnormality Code No. (section in 4 dig-
its and phenomenon in 2 digits)
[4]: Total number of occurrence
[5]: Service meter reading at the initial
occurrence
a See the operator menu "Failure codes
table".
30 Testing and adjusting
PC800, 850-8

Advertisement

Table of Contents
loading

Table of Contents