32. Disconnect branch hose (34) and main pump
drain hose (35).
33. Disconnect breather hose (36) and EPC basic
pressure hose (37).
34. Disconnect clamp (38) from the bottom of main
pump assembly (39).
35. Sling main pump assembly (39) temporarily
and remove 6 bolts (40).
8
36. Lift off main pump assembly (39).
4
Main pump assembly: 550 kg
[*3]
50 Disassembly and assembly
PC800, 850-8