Komatsu Galeo PC800-8 Shop Manual page 417

Hydraulic excavator
Table of Contents

Advertisement

30 Testing and adjusting
5) Resetting Electrical Systems
a Resetting Electrical Systems (deletion)
is possible only with the electrical sys-
tem. The failure history in the mechani-
cal system cannot be reset.
a For resetting any specific or all informa-
tion in the Electrical Systems, follow the
operation explained below.
i)
Through the following switch operation,
call the resetting display in the display of
Electrical Systems.
Switch operation: [E] +[1] o [2] o
[3]
a This is the same switch operation in
changing the display to Service
Menu.
PC800, 850-8
ii) Operate the switch, following the instruc-
tions shown in the resetting display.
a When resetting specific information
only, call the display of that specific
information and reset it with either
[E] switch or [R] switch.
a When resetting all the information, a
display of any information will do.
SEN00913-02
23

Advertisement