9.
Using tool L10, apply standard pressure to
roller oil filler port, and check for leakage of air
from seal.
a Standard pressure: 0.1 MPa {1 kg/cm
a Method of checking
The standard pressure shall be main-
tained for 10 seconds and the indicator of
the gauge shall not go down.
10. Using tool L10, fill track roller assembly with
oil, then tighten plug (11).
5
Track roller oil:
3
Plug: 16.7 – 37.2 Nm {1.7 – 3.8 kgm}
11
24
2
}
420 – 480 cc (GO140)