4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
4)
Print the Maintenance Counter/Parameter Settings and the Self-Diagnostic Test result to confirm
the RFID Module status.
Parameters for
the RFID Module
Self-diagnosis of the
RFID Module status
5)
If "RFID NG" (No Good) is printed, check the cable connections and parameter settings related to
the RFID Module again.
6) Try a read and write of the RFID tag by using the RFID Analyze Tool. When you do not have a
PC at hand, perform a simplified read test in the system mode to confirm the data can be read.
In case that the read/write accuracy needs to be enhanced, make an adjustment of the parameter
setting in the System Mode. (Refer to Section 11 and Section 5.12.)
NOTE:
Available RFID tags
EPC Class 0 (Read only)
EPC Class 1
EPC Class 1 Gen2 (Only when the RFID module supports Gen2)
ISO 18000-6B
Mantenimiento Periféricos Informáticos C/Canteras,15 28860 Paracuellos de Jarama Madrid Tel: 91 748 16 04 www.mpi.com.es
Example: Maintenance Counter/Parameter Settings Label
Make sure that [U1] is selected and other parameters for the
RFID Module are printed as follows.
WEP KEY #3
[101112131415161718191A1B1C]
WEP KEY #4
[202122232425262728292A2B2C]
RFID MODULE
[U1]
RFID TAG TYPE
[EPC CI Gen2
RFID ERR CHECK
[OFF]
RFID RETRY
[ 3]
RFID RD CYCLE
[ 5]
RFID WT CYCLE
[ 5]
RFID ADJ RETRY
[+00mm]
RFID POWER LEV
[50]
Example: Self-Diagnostic Test Label
Make sure that "RFID OK" is printed.
SENSOR2
[H] 23ºC [A]22ºC
[R]4.2V
[T]2.5V
[RANK]7
EXP. I/O
NG
EX. 232C
NG
****
RFID
OK
V
4-55
(Revision Date: Feb. 15, 2007)
4.10 RFID MODULE (B-9704-RFID-U1-US/EU/EU-R)
]
[4.0sec.]
Initial values
[2.0sec.]
US/EU mode: 251
EU-R model: 50
[E]0.6V
Version No.
EO18-33012B