4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
12) Insert folded tag paper (1.5-mm thick) between the print head and the platen, and then turn the
head lever to Lock position. Insert the head up arm into the plunger of the solenoid. While
holding down the head up arm slightly, lift the solenoid. Secure the solenoid to the frame with the
two SM-4x8 screws keeping the solenoid in contact with the spacer.
Head Up Arm
Spacer
13) Attach the cable clamp to the frame of the printer. Fix the solenoid cable with this cable clamp.
NOTE: Be careful not to snag the solenoid harness when running it.
Mantenimiento Periféricos Informáticos C/Canteras,15 28860 Paracuellos de Jarama Madrid Tel: 91 748 16 04 www.mpi.com.es
Solenoid
Cable Clamp
4.15 RIBBON SAVING MODULE (B-9904-R2-QM-R)
Plunger
Frame
Solenoid
4-104
EO18-33012B
SM-4x8 Screw
Solenoid Cable