4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
4.24.1 Applicable Model
(1)
This optional device is intended for the following models:
B-SX4T-GS20-QM-R and B-SX5T-TS22-QM-R, RFID ready printer.
An RFID Ready printer can be identified by the model name sticker on the front of the printer.
Be careful not to install this product in the B-SX4T-GS10-QQ/QQ-US and B-SX5T-TS10-QQ/QQ-
US RFID Ready printers.
(2)
To use this device, printer firmware V4.5 or greater is required. Upgrade the firmware to V4.5 or
greater, if necessary. For the downloading procedure, refer to the B-SX4T/SX5T Series Maintenance
Manual.
Note that a RAM clear needs to be performed after downloading, so print out the maintenance
counter and parameter settings prior to downloading. After performing a RAM clear, restore the
printer parameter settings to the former states.
As from the January 2009 production (Serial Number 2809Axxxxxx and after), the AU (Australia)
(3)
specification has been supported by the B-SX704-RFID-U2-US-R RFID Module. Also the KR
(South Korea) and TW (Taiwan) specifications have been added.
The firmware of the B-SX4T/SX5T-R series barcode printer should be V4.7 or greater. If V4.6A
or less, please install the firmware V4.7 into the printer.
Make sure the firmware version is V4.7 and greater when turning on the printer.
ONLINE
When the firmware version is V4.6A or less, it is necessary to upgrade the firmware to V4.7 and
greater. For the downloading procedure, refer to the B-SX4T/SX5T Series Maintenance Manual.
For the printer to which back side the sticker MAIN4-R is attached, the firmware V5.0 and greater has
been installed. Since the firmware V5.0 and greater is exclusive to this printer, do not install the
firmware V4.7 into it.
To use this device, printer firmware V4.7 or greater is required. Upgrade the firmware to V4.5 or
greater, if necessary. For the downloading procedure, refer to Section 7 PROGRAM DOWN LOAD.
Note that a RAM clear needs to be performed after downloading, so print out the maintenance
counter and parameter settings prior to downloading. After performing a RAM clear, restore the
printer parameter settings to the former states.
Destination Code Setting should be performed in the system mode of the printer according to the
destination.
(4)
The countries where the use of this device is allowed are as follows:
Model Name
B-SX704-RFID–U2-US-R
Mantenimiento Periféricos Informáticos C/Canteras,15 28860 Paracuellos de Jarama Madrid Tel: 91 748 16 04 www.mpi.com.es
V4.7
Setting
US
AU
KR
TW
4.24 RFID MODULE (B-SX704-RFID-U2-US-R)
Frequency Band
UHF 902.75 to 927.5MHz
UHF 918.25 to 925.75 MHz
UHF 910.4 to 913.6 MHz
UHF 922.25 to 927.25 MHz
4-182
EO18-33012B
(Revision Date Feb. 6, 2009)
Applicable Countries
U.S.A., Canada
Australia
Korea
Taiwan