IC-KP2-2HB18-2V1
Commands
Master -> Slave
Address
CH1
...
RWw
n+1+N
Slave -> Master
Address
CH1
RWr n
RWr n+1
n:
*:
1)
:
The R/W head makes only one attempt to write a read only code.
IPC11:
IDC-...-1K:
Type IDC-...-1K tags can be programmed in such a way that they are compatible
with the type ICC-... read only carriers. This programming occupies the first 8
bytes in the tag. The read/write commands can be used to access the remaining
memory.
You must set the tag type '50' in order to program type IDC-...-1K tags. To do this,
transmit the command SX or EX.
The value range contains 7 characters:
72
Bit no.
CH2*
15
...
RWw
1)
1)
n+9+N
Bit no.
CH2*
15
RWr n+8
RWr n+9
Address in master module, specified by the assignment of the stations
If 2 channels are used
N =<FixLen>/2 rounded up
<FixLen>
=
<FixType>
=
<FixLen>
=
<FixType>
=
<Data>
=
the first 3 characters contain the values 0 ... F (hexadecimal code)
the last 4 characters contain the values 0 ... 9 (decimal code)
8
<Data>
<Data> (low byte)
8
<FixLen>
<ReplyCounter>
5
'02' ASCII (30h 32h), the read only code cannot be
changed
'11' ASCII (31h 31h), the read only code can be overwritten
7
The first 3 bytes are hexadecimal (0h ... Fh), the last 4
bytes are decimal (0d ... 9d).
'52' ASCII (35h 32h), the read only code can be overwritten
(Byte 1 to 3): 0x30 ... 0x39; 0x41...0x46
(Byte 4 to 7): 0x30...0x39
7
<Data>
<Data>
7
0
0
0
1
1
1
1
<Status>
0
0
1