2. Commissioning

2.1.2 Address assignment of the CPX terminal

2-14
Basic rules for addressing
Inputs and outputs
The address assignment of the inputs is independent of
the outputs.
Counting mode does not depend on the position of the
bus node (the bus node counts as a module with 0 inputs
and 0 outputs)
Counting is from left to right, in ascending order without
gaps
Sequence:
Input/output words of the analogue modules,
Input/output words of the technology modules (word-
oriented),
Input/output bits of the electric inputs and outputs
(including valves),
The 8 status bits follow the input bits as from the next
byte,
The 16 bits of the I/O diagnostics interface follow the
input/output bits as from the next word.
Note
If two addresses are assigned for one valve position, the
assignment applies:
– less significant address: pilot solenoid coil 14
– higher-value address: pilot solenoid coil 12
Festo P.BE-CPX-FB6-EN en 1207c