Parameter Descriptions
0-65 Quick Menu Password
Range:
200
[-9999 -
*
9999]
3
3
0-66 Access to Quick Menu w/o Password
If 0-61 Access to Main Menu w/o Password is set to [0] Full access
then this parameter is ignored.
Option:
[0]
Full access
*
[1]
LCP: Read only Prevents unauthorised editing of Quick
[3]
Bus: Read only Read only functions for Quick Menu
[5]
All: Read only
0-67 Bus Password Access
Range:
0
[0 - 9999] Writing to this parameter enables users to unlock
*
34
VLT
Function:
Define the password for access to the Quick
Menu via the [Quick Menu] key. If
parameter 0-66 Access to Quick Menu w/o
Password is set to [0] Full access, this
parameter is ignored.
Function:
Disables the password defined in
parameter 0-65 Quick Menu Password.
Menu parameters.
parameters on Fieldbus and/or FC standard
bus.
Read only function for Quick Menu
parameters on LCP, Fieldbus or FC standard
bus.
Function:
the frequency converter from bus/MCT 10 Set-up
Software.