Danfoss VLT AutomationDrive FC 302 Programming Manual page 196

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Parameter Lists
Par. No. #
Parameter description
Term. X30/11 Low Ref./Feedb.
6-34
Value
Term. X30/11 High Ref./Feedb.
6-35
Value
Term. X30/11 Filter Time
4
4
6-36
Constant
6-4* Analog Input 4
6-40
Terminal X30/12 Low Voltage
6-41
Terminal X30/12 High Voltage
Term. X30/12 Low Ref./Feedb.
6-44
Value
Term. X30/12 High Ref./Feedb.
6-45
Value
Term. X30/12 Filter Time
6-46
Constant
6-5* Analog Output 1
6-50
Terminal 42 Output
6-51
Terminal 42 Output Min. Scale
6-52
Terminal 42 Output Max. Scale
6-53
Term 42 Output Bus Ctrl
Terminal 42 Output Timeout
6-54
Preset
6-55
Analog Output Filter
6-6* Analog Output 2
6-60
Terminal X30/8 Output
6-61
Terminal X30/8 Min. Scale
6-62
Terminal X30/8 Max. Scale
6-63
Terminal X30/8 Bus Control
Terminal X30/8 Output Timeout
6-64
Preset
6-7* Analog Output 3
6-70
Terminal X45/1 Output
6-71
Terminal X45/1 Min. Scale
6-72
Terminal X45/1 Max. Scale
6-73
Terminal X45/1 Bus Control
Terminal X45/1 Output Timeout
6-74
Preset
6-8* Analog Output 4
6-80
Terminal X45/3 Output
6-81
Terminal X45/3 Min. Scale
6-82
Terminal X45/3 Max. Scale
6-83
Terminal X45/3 Bus Control
Terminal X45/3 Output Timeout
6-84
Preset
194
®
VLT
AutomationDrive FC 301/302
Default value
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
ExpressionLimit
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
[0] Off
ExpressionLimit
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
ExpressionLimit
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
ExpressionLimit
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
Danfoss A/S © Rev. 10/2014 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
Conver-
Type
sion index
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
MG33MJ02