Danfoss VLT AutomationDrive FC 302 Programming Manual page 202

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Parameter Lists
Par. No. #
Parameter description
12-98
Interface Counters
12-99
Media Counters
4.1.16 13-** Smart Logic
4
4
Par. No. #
Parameter description
13-0* SLC Settings
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-1* Comparators
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-1* RS Flip Flops
13-15
RS-FF Operand S
13-16
RS-FF Operand R
13-2* Timers
13-20
SL Controller Timer
13-4* Logic Rules
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-5* States
13-51
SL Controller Event
13-52
SL Controller Action
4.1.17 14-** Special Functions
Par.
Parameter description
No. #
14-0* Inverter Switching
14-00 Switching Pattern
14-01 Switching Frequency
14-03 Overmodulation
14-04 PWM Random
14-06 Dead Time Compensation
14-1* Mains On/Off
14-10 Mains Failure
14-11 Mains Voltage at Mains Fault
14-12 Function at Mains Imbalance
14-13 Mains Failure Step Factor
14-14 Kin. back-up Timeout
14-15 Kin. back-up Trip Recovery Level
14-16 Kin. back-up Gain
200
®
VLT
AutomationDrive FC 301/302
Default value
4-set-up
4000 N/A
All set-ups
0 N/A
All set-ups
Default value
4-set-up
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] Do not reset SLC
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
1 set-up
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
Default value
ExpressionLimit
ExpressionLimit
[1] On
[0] Off
[1] On
[0] No function
ExpressionLimit
[0] Trip
1 N/A
60 s
ExpressionLimit
100%
Danfoss A/S © Rev. 10/2014 All rights reserved.
FC 302
Change
only
during
operation
TRUE
TRUE
FC 302
Change
only
during
operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
Conver-
Type
sion index
0
Uint32
0
Uint32
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Int32
-
Uint8
-
Uint8
-3
TimD
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Conver-
Type
sion
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-1
Uint8
0
Uint8
-3
Uint32
0
Uint32
MG33MJ02

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?

This manual is also suitable for:

Vlt automationdrive fc 301

Table of Contents

Save PDF