Parameter Lists
Par. No. # Parameter description
33-80
Activated Program Number
33-81
Power-up State
33-82
Drive Status Monitoring
33-83
Behaviour afterError
33-84
Behaviour afterEsc.
MCO Supplied by External
33-85
24VDC
33-86
Terminal at alarm
33-87
Terminal state at alarm
33-88
Status word at alarm
33-9* MCO Port Settings
33-90
X62 MCO CAN node ID
33-91
X62 MCO CAN baud rate
X60 MCO RS485 serial
33-94
termination
X60 MCO RS485 serial baud
33-95
rate
4.1.24 34-** MCO Data Readouts
Par. No. #
Parameter description
34-0* PCD Write Par.
34-01
PCD 1 Write to MCO
34-02
PCD 2 Write to MCO
34-03
PCD 3 Write to MCO
34-04
PCD 4 Write to MCO
34-05
PCD 5 Write to MCO
34-06
PCD 6 Write to MCO
34-07
PCD 7 Write to MCO
34-08
PCD 8 Write to MCO
34-09
PCD 9 Write to MCO
34-10
PCD 10 Write to MCO
34-2* PCD Read Par.
34-21
PCD 1 Read from MCO
34-22
PCD 2 Read from MCO
34-23
PCD 3 Read from MCO
34-24
PCD 4 Read from MCO
34-25
PCD 5 Read from MCO
34-26
PCD 6 Read from MCO
34-27
PCD 7 Read from MCO
34-28
PCD 8 Read from MCO
34-29
PCD 9 Read from MCO
34-30
PCD 10 Read from MCO
34-4* Inputs & Outputs
34-40
Digital Inputs
34-41
Digital Outputs
34-5* Process Data
34-50
Actual Position
34-51
Commanded Position
®
VLT
AutomationDrive Programming Guide
Default value
4-set-up
-1 N/A
2 set-ups
[1] Motor on
2 set-ups
[1] On
2 set-ups
[0] Coast
2 set-ups
[0] Controlled stop
2 set-ups
[0] No
2 set-ups
[0] Relay 1
2 set-ups
[0] Do nothing
2 set-ups
0 N/A
2 set-ups
127 N/A
2 set-ups
[20] 125 Kbps
2 set-ups
[0] Off
2 set-ups
[2] 9600 Baud
2 set-ups
Default value
4-set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
®
MG33MG02 - VLT
is a registered Danfoss trademark
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
Type
Int8
Uint8
Uint8
Uint8
Uint8
4
4
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Type
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Int32
Int32
197