Danfoss VLT AutomationDrive FC 300 Programming Manual page 177

Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

Parameter Lists
Par. No. # Parameter description
Min Speed Normal Magnetising
1-52
[Hz]
1-53
Model Shift Frequency
Voltage reduction in
1-54
fieldweakening
1-55
U/f Characteristic - U
1-56
U/f Characteristic - F
1-58
Flystart Test Pulses Current
1-59
Flystart Test Pulses Frequency
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Damping
Resonance Damping Time
1-65
Constant
1-66
Min. Current at Low Speed
1-67
Load Type
1-68
Minimum Inertia
1-69
Maximum Inertia
1-7* Start Adjustments
1-70
PM Start Mode
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-74
Start Speed [RPM]
1-75
Start Speed [Hz]
1-76
Start Current
1-8* Stop Adjustments
1-80
Function at Stop
Min Speed for Function at Stop
1-81
[RPM]
Min Speed for Function at Stop
1-82
[Hz]
1-83
Precise Stop Function
1-84
Precise Stop Counter Value
Precise Stop Speed Compensation
1-85
Delay
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Resource
1-94
ATEX ETR cur.lim. speed reduction
1-95
KTY Sensor Type
1-96
KTY Thermistor Resource
1-97
KTY Threshold level
1-98
ATEX ETR interpol. points freq.
1-99
ATEX ETR interpol points current
®
VLT
AutomationDrive Programming Guide
Default value
ExpressionLimit
ExpressionLimit
0 V
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
100 %
ExpressionLimit
ExpressionLimit
100 %
5 ms
ExpressionLimit
[0] Passive load
ExpressionLimit
ExpressionLimit
[0] Rotor Detection
0 s
[2] Coast/delay time
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 A
[0] Coast
ExpressionLimit
ExpressionLimit
[0] Precise ramp stop
100000 N/A
10 ms
[0] No protection
ExpressionLimit
[0] None
0 %
[0] KTY Sensor 1
[0] None
80 °C
ExpressionLimit
ExpressionLimit
®
MG33MG02 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
x
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
FALSE
All set-ups
x
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
1 set-up
x
TRUE
1 set-up
x
TRUE
2 set-ups
x
TRUE
Conver-
Type
sion index
-1
Uint16
-1
Uint16
0
Uint8
4
-1
Uint16
-1
Uint16
0
Uint16
0
Uint16
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
0
Uint32
-
Uint8
-4
Uint32
-4
Uint32
-
Uint8
-1
Uint8
-
Uint8
-
Uint8
67
Uint16
-1
Uint16
-2
Uint32
-
Uint8
67
Uint16
-1
Uint16
-
Uint8
0
Uint32
-3
Uint8
-
Uint8
-
Uint16
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
100
Int16
-1
Uint16
0
Uint16
175
4

Advertisement

Table of Contents
loading

Table of Contents