Parameter Lists
4.1.5 2-** Brakes
Par. No. #
Parameter description
2-0* DC-Brake
2-00
DC Hold Current
2-01
DC Brake Current
4
4
2-02
DC Braking Time
2-03
DC Brake Cut In Speed [RPM]
2-04
DC Brake Cut In Speed [Hz]
2-05
Maximum Reference
2-06
Parking Current
2-07
Parking Time
2-1* Brake Energy Funct.
2-10
Brake Function
2-11
Brake Resistor (ohm)
2-12
Brake Power Limit (kW)
2-13
Brake Power Monitoring
2-15
Brake Check
2-16
AC brake Max. Current
2-17
Over-voltage Control
2-18
Brake Check Condition
2-19
Over-voltage Gain
2-2* Mechanical Brake
2-20
Release Brake Current
2-21
Activate Brake Speed [RPM]
2-22
Activate Brake Speed [Hz]
2-23
Activate Brake Delay
2-24
Stop Delay
2-25
Brake Release Time
2-26
Torque Ref
2-27
Torque Ramp Up Time
2-28
Gain Boost Factor
2-29
Torque Ramp Down Time
2-3* Adv. Mech Brake
2-30
Position P Start Proportional Gain
2-31
Speed PID Start Proportional Gain
2-32
Speed PID Start Integral Time
Speed PID Start Lowpass Filter
2-33
Time
4.1.6 3-** Reference/Ramps
Par. No. # Parameter description
3-0* Reference Limits
3-00
Reference Range
3-01
Reference/Feedback Unit
3-02
Minimum Reference
3-03
Maximum Reference
3-04
Reference Function
3-1* References
176
®
VLT
AutomationDrive Programming Guide
Default value
4-set-up
50 %
All set-ups
50 %
All set-ups
10 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
MaxReference (P303)
All set-ups
50 %
All set-ups
3 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[0] Off
All set-ups
100 %
All set-ups
[0] Disabled
All set-ups
[0] At Power Up
All set-ups
100 %
All set-ups
ImaxVLT (P1637)
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 s
All set-ups
0 s
All set-ups
0.20 s
All set-ups
0 %
All set-ups
0.2 s
All set-ups
1 N/A
All set-ups
0 s
All set-ups
0.0000 N/A
All set-ups
0.0150 N/A
All set-ups
200.0 ms
All set-ups
10.0 ms
All set-ups
Default value
4-set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Sum
All set-ups
®
MG33MG02 - VLT
is a registered Danfoss trademark
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
TRUE
0
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-3
TRUE
0
TRUE
-1
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-1
TRUE
-
TRUE
-
TRUE
0
TRUE
-2
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-1
TRUE
-2
TRUE
-2
TRUE
-1
TRUE
-2
TRUE
-1
TRUE
-4
TRUE
-4
TRUE
-4
TRUE
-4
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Int32
Uint16
Uint16
Uint8
Uint16
Uint32
Uint8
Uint8
Uint32
Uint8
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Uint8
Uint16
Int16
Uint8
Uint16
Uint8
Uint32
Uint32
Uint32
Uint16
Type
Uint8
Uint8
Int32
Int32
Uint8