Parameter Descriptions
8-13 Configurable Status Word STW
Option:
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
3
3
[65] Comparator 5
[70] Logic Rule 0
[71] Logic Rule 1
[72] Logic Rule 2
[73] Logic Rule 3
[74] Logic Rule 4
[75] Logic Rule 5
[80] SL digital out A
[81] SL digital out B
[82] SL digital out C
[83] SL digital out D
[84] SL digital out E
[85] SL digital out F
[86] ATEX ETR cur. alarm
[87] ATEX ETR freq. alarm
[88] ATEX ETR cur. warning
[89] ATEX ETR freq. warning
[90] Safe Function active
[91] Safe Opt. Reset req.
8-14 Configurable Control Word CTW
Option:
[0] None
[1] Profile default
[2] CTW Valid,
active low
[3] Safe Option
Reset
[4] PID error
inverse
[5] PID reset I
part
[6] PID enable
114
®
VLT
Function:
Function:
Selection of control word bit 10 if it is active
low or active high.
When enabled, it inverts the resulting error
from the process PID controller. Available
only if "Configuration Mode" is set to "Surface
Winder", "Extended PID Speed OL" or
"Extended PID Speed CL".
When enabled, resets the I-part of the Process
PID controller. Equivalent to 7-40 Process PID
I-part Reset. Available only if "Configuration
Mode" is set to "Surface Winder", "Extended
PID Speed OL" or "Extended PID Speed CL".
When enabled, enables the extended process
PID controller. Equivalent to 7-50 Process PID
Extended PID. Available only if "Configuration
Mode" is set "Extended PID Speed OL" or
"Extended PID Speed CL".
MG33MG02 - VLT
AutomationDrive Programming Guide
8-19 Product Code
Range:
Size
related
*
3.10.3 8-3* FC Port Settings
8-30 Protocol
Option:
[0]
FC
*
[1]
FC MC
[2]
Modbus RTU
8-31 Address
Range:
Size related
*
8-32 FC Port Baud Rate
Option:
[0] 2400 Baud
[1] 4800 Baud
[2] 9600 Baud
[3] 19200 Baud
[4] 38400 Baud
[5] 57600 Baud
[6] 76800 Baud
[7] 115200 Baud
8-33 Parity / Stop Bits
Option:
[0]
Even Parity, 1 Stop Bit
[1]
Odd Parity, 1 Stop Bit
[2]
No Parity, 1 Stop Bit
[3]
No Parity, 2 Stop Bits
8-34 Estimated cycle time
Range:
0 ms
[0 - 1000000
*
ms]
®
is a registered Danfoss trademark
Function:
[0 - 2147483647 ] Select [0] to readout the actual
fieldbus product code
according to the mounted
fieldbus option. Select [1] to
readout the actual Vendor ID.
Function:
Select the protocol to be used. Changing
protocol will not be effective until after
powering off the frequency converter.
Function:
[ 1 - 255 ] Enter the address for the FC (standard)
port.
Valid range: 1-126.
Function:
Baud rate selection for the FC (standard) port.
Function:
In noisy environments, the interface may
be blocked by due to overload of bad
frames. This parameter specifies the time
between two consecutive frames on the
network. If the interface does not detect
valid frames in that time it flushes the
receive buffer.
Function: