Parameter Lists
Par. No. # Parameter description
6-71
Terminal X45/1 Min. Scale
6-72
Terminal X45/1 Max. Scale
6-73
Terminal X45/1 Bus Control
Terminal X45/1 Output Timeout
6-74
Preset
4
4
6-8* Analog Output 4
6-80
Terminal X45/3 Output
6-81
Terminal X45/3 Min. Scale
6-82
Terminal X45/3 Max. Scale
6-83
Terminal X45/3 Bus Control
Terminal X45/3 Output Timeout
6-84
Preset
4.1.10 7-** Controllers
Par. No. #
Parameter description
7-0* Speed PID Ctrl.
7-00
Speed PID Feedback Source
7-02
Speed PID Proportional Gain
7-03
Speed PID Integral Time
7-04
Speed PID Differentiation Time
7-05
Speed PID Diff. Gain Limit
7-06
Speed PID Lowpass Filter Time
7-07
Speed PID Feedback Gear Ratio
7-08
Speed PID Feed Forward Factor
Speed PID Error Correction w/
7-09
Ramp
7-1* Torque PI Ctrl.
7-12
Torque PI Proportional Gain
7-13
Torque PI Integration Time
7-19
Current Controller Rise Time
7-2* Process Ctrl. Feedb
7-20
Process CL Feedback 1 Resource
7-22
Process CL Feedback 2 Resource
7-3* Process PID Ctrl.
Process PID Normal/ Inverse
7-30
Control
7-31
Process PID Anti Windup
7-32
Process PID Start Speed
7-33
Process PID Proportional Gain
7-34
Process PID Integral Time
7-35
Process PID Differentiation Time
7-36
Process PID Diff. Gain Limit
7-38
Process PID Feed Forward Factor
7-39
On Reference Bandwidth
7-4* Adv. Process PID I
7-40
Process PID I-part Reset
7-41
Process PID Output Neg. Clamp
7-42
Process PID Output Pos. Clamp
182
®
VLT
AutomationDrive Programming Guide
Default value
4-set-up
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
Default value
4-set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5 N/A
All set-ups
ExpressionLimit
All set-ups
1 N/A
All set-ups
0 %
All set-ups
300 RPM
All set-ups
100 %
All set-ups
0.020 s
All set-ups
100 %
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
[0] Normal
All set-ups
[1] On
All set-ups
0 RPM
All set-ups
0.01 N/A
All set-ups
10000 s
All set-ups
0 s
All set-ups
5 N/A
All set-ups
0 %
All set-ups
5 %
All set-ups
[0] No
All set-ups
-100 %
All set-ups
100 %
All set-ups
®
MG33MG02 - VLT
is a registered Danfoss trademark
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
FC 302
Change
Conver-
only
during
sion index
operation
FALSE
-
TRUE
-3
TRUE
-4
TRUE
-4
TRUE
-1
TRUE
-4
FALSE
-4
FALSE
0
TRUE
67
TRUE
0
TRUE
-3
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
67
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-1
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
0
Type
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Type
Uint8
Uint16
Uint32
Uint16
Uint16
Uint16
Uint32
Uint16
Uint32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint32
Uint16
Uint16
Uint16
Uint8
Uint8
Int16
Int16