Parameter Lists
4.1.16 14-** Special Functions
Par. No. # Parameter description
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
4
4
14-03
Overmodulation
14-04
PWM Random
14-06
Dead Time Compensation
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-13
Mains Failure Step Factor
14-14
Kin. Backup Time Out
14-15
Kin. Backup Trip Recovery Level
14-2* Trip Reset
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-24
Trip Delay at Current Limit
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
Current Lim Ctrl, Proportional
14-30
Gain
Current Lim Ctrl, Integration
14-31
Time
14-32
Current Lim Ctrl, Filter Time
14-35
Stall Protection
14-4* Energy Optimising
14-40
VT Level
14-41
AEO Minimum Magnetisation
14-42
Minimum AEO Frequency
14-43
Motor Cosphi
14-5* Environment
14-50
RFI Filter
14-51
DC Link Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-56
Capacitance Output Filter
14-57
Inductance Output Filter
Actual Number of Inverter
14-59
Units
14-7* Compatibility
14-72
Legacy Alarm Word
14-73
Legacy Warning Word
14-74
Leg. Ext. Status Word
188
®
VLT
AutomationDrive Programming Guide
Default value
4-set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] On
All set-ups
[0] Off
All set-ups
[1] On
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
[0] Trip
All set-ups
1 N/A
All set-ups
60 s
All set-ups
ExpressionLimit
All set-ups
[0] Manual reset
All set-ups
ExpressionLimit
All set-ups
[0] Normal operation
All set-ups
ExpressionLimit
2 set-ups
60 s
All set-ups
60 s
All set-ups
ExpressionLimit
All set-ups
[0] No action
All set-ups
0 N/A
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] Enabled
All set-ups
66 %
All set-ups
ExpressionLimit
All set-ups
10 Hz
All set-ups
ExpressionLimit
All set-ups
[1] On
1 set-up
ExpressionLimit
All set-ups
[0] Auto
All set-ups
[1] Warning
All set-ups
[0] No Filter
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
®
MG33MG02 - VLT
is a registered Danfoss trademark
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
0
TRUE
-
TRUE
-1
TRUE
0
TRUE
-3
TRUE
-
TRUE
0
TRUE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
FALSE
0
FALSE
-3
TRUE
-4
FALSE
-
FALSE
0
TRUE
0
TRUE
0
TRUE
-2
x
FALSE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
-7
FALSE
-6
x
FALSE
0
FALSE
0
FALSE
0
FALSE
0
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint32
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint8
Uint32
Uint32
Uint32
Need help?
Do you have a question about the VLT AutomationDrive FC 300 and is the answer not in the manual?