YASKAWA Z1000U Series Programming Manual page 262

Hvac matrix low harmonic drive for hvac applications
Hide thumbs Also See for Z1000U Series:
Table of Contents

Advertisement

A.18 Defaults by Drive Model
No.
Name
Drive Model
o2-04
Drive Model Selection
E2-11
Motor Rated Output
E2-01
Motor Rated Current
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-05
Motor Line-to-Line Resistance
E2-06
Motor Leakage Inductance
Motor Iron Loss for Torque
E2-10
Compensation
Motor Code Selection (for PM
E5-01
Motors)
Momentary Power Loss Ride-Thru
L2-02
Time
Momentary Power Loss Minimum
L2-03
Baseblock Time
Momentary Power Loss Voltage
L2-04
Recovery Time
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
Carrier Frequency Reduction
L8-38
Selection
n1-03
Hunting Prevention Time Constant
No.
o2-04
E2-11 (E4-11)
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
Current Control Gain during Speed Search
b3-08
(Speed Estimation Type)
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line-to-Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection (for PM Motors)
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L2-21
Low Input Voltage Detection Level
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
262
Unit
Hex.
kW (HP)
A
Hz
A
Ω
%
W
Hex.
s
s
s
°C
ms
Table A.13 400 V Class Drives Default Settings by Drive Model Selection
Name
Drive Model
Drive Model Selection
Motor Rated Output
4o0180
4o0216
A5
A6
110 (150)
132 (175)
150 (200)
156
190
1.4
1.4
40
49
0.056
0.046
20
20
1760
2150
1246
1247
1.5
1.7
1
1
300
300
130
130
0
0
1
1
30
30
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
Default Settings
4o0240
4o0302
4o0361
A7
A8
185 (250)
220 (300)
223
270
1.38
1.35
58
70
0.035
0.029
20
20
2350
2850
1248
1249
1.7
1.8
1
1
300
300
130
130
0
0
1
1
30
30
Unit
Default Settings
4o0361
Hex.
A9
kW (HP)
220 (300)
%
60
0.7
0.8
s
2.00
30.57
2
3.60
kgm
1
A
310
Hz
1.3
A
81
Ω
0.025
%
20
W
3200
Hex.
124A
s
1.9
s
1
s
300
V
300
°C
130
0
1
ms
30
s
0.864
4o0414
A9
AA
260 (350)
310
370
1.3
1.3
81
96
0.025
0.02
20
20
3200
3700
124A
FFFF
1.9
2
1
1
300
300
130
130
0
0
1
1
30
100
4o0414
AA
260 (350)
60
0.7
0.8
2.00
27.13
4.10
1
370
1.3
96
0.02
20
3700
FFFF
2
1
300
300
130
0
1
100
0.91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z1000 cimr-zu series

Table of Contents