O: Operator-Related Settings; O: Operator-Related Settings; O1: Hoa Keypad Display Selection - YASKAWA Z1000U Series Programming Manual

Hvac matrix low harmonic drive for hvac applications
Hide thumbs Also See for Z1000U Series:
Table of Contents

Advertisement

A.12 o: Operator-Related Settings
A.12 o: Operator-Related Settings
The o parameters set up the HOA keypad displays.
u

o1: HOA Keypad Display Selection

No.
(Addr.
Name
Hex)
o1-01
Drive Mode Unit
(0500)
Monitor Selection
o1-02
User Monitor Selection
(0501)
after Power Up
o1-03
HOA Keypad Display
(0502)
Selection
o1-05
(0504)
LCD Contrast Control
o1-06
User Monitor Selection
(0517)
Mode
o1-07
Second Line Monitor
(0518)
Selection
o1-08
Third Line Monitor
(0519)
Selection
o1-09
Frequency Reference
(051C)
Display Units
o1-10
User-Set Display Units
(0520)
Maximum Value
o1-11
User-Set Display Units
(0521)
Decimal Display
Frequency Reference
o1-13
and Frequency Related
(3105)
Monitor Custom Units 1
236
LCD Display
Selects the content of the last monitor that is shown when
scrolling through Drive Mode display. Enter the last three digits
User Monitor Sel
of the monitor parameter number to be displayed: Uo-oo.
Power-On Monitor
1: Frequency reference (U1-01)
1: Frequency Ref
2: Direction
2: FWD/REV
3: Output frequency (U1-02)
3: Output Freq
4: Output current (U1-03)
4: Output Current
5: User Monitor
5: User Monitor
Sets the units the drive should use to display the frequency
Display Unit Sel
reference and motor speed monitors.
0: 0.01 Hz
0: 0.01 Hz
1: 0.01%
1: 0.01% (100% = E1-04)
2: r/min
2: r/min (calculated using the number of motor poles setting in
3: User Units
E2-04 or E5-04)
3: User-selected units (set by o1-10 and o1-11)
Sets the contrast of the LCD operator.
LCD Contrast
0: 3 Monitor Sequential
Monitor Mode Sel
(Displays the next two sequential monitors)
0: 3 Mon Sequential
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor are
1: 3 Mon Selectable
shown)
Selects the monitor that is shown in the second line.
Enter the last three digits of the monitor parameter number to
2nd Monitor Sel
be displayed: Uo-oo. For example, set "403" to display
monitor parameter U4-03.
Selects the monitor that is shown in the third line.
Enter the last three digits of the monitor parameter number to
3rd Monitor Sel
be displayed: Uo-oo. For example, set "403" to display
monitor parameter U4-03.
Sets unit display for the frequency reference parameters and
Fref Disp Unit
frequency related monitors when o1-03 > 40.
0: WC
0: WC (Inch of water)
1: PSI
1: PSI (Pounds per square inch)
2: GPM
2: GPM (Gallons per minute)
3: °F
3: F (Degrees Fahrenheit)
4: CFM
4: CFM (Cubic feet per minute)
5: CMH
5: CMH (Cubic meters per hour)
6: LPH
6: LPH (Liters per hour)
7: LPS
7: LPS (Liters per second)
8: Bar
8: Bar (Bar)
9: Pa
9: Pa (Pascal)
10: °C
10: C (Degrees Celsius)
11: Mtr
11: Mtr (Meters)
12: Ft
12: Ft (Feet)
13: LPM
13: LPM (Liters per minute)
14: CMM
14: CMM (Cubic meters per minute)
15: Custom unit
15: Custom units (Determined by o1-12)
16: No Unit
16: None
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output
UserDisp Scaling
frequency.
o1-11 sets the position of the decimal position.
UserDisp Dec
Sets the customer-specified unit display for the frequency
Fref Cust Unit 1
reference parameters and frequency related monitors when
o1-03 = 3 and o1-09 = 15 as custom units.
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
Description
Values
Page
Default: 106
Range: 104 to
133
914
<1>
Default:
133
Range: 1 to 5
Default: 0
133
Range: 0 to 3
Default: 3
Min.: 0
134
Max.: 5
<2>
Default:
133
Range: 0, 1
<3>
Default:
133
Range: 101 to
699
<4>
Default:
133
Range: 101 to
699
Default: 16
133
Range: 0 to 16
<5>
Default:
135
Range: 1 to
60000
<5>
Default:
135
Range: 0 to 3
Default: 41
135
Range: 30 to 7A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z1000 cimr-zu series

Table of Contents