B2: Dc Injection Braking; B3: Speed Search - YASKAWA Z1000U Series Programming Manual

Hvac matrix low harmonic drive for hvac applications
Hide thumbs Also See for Z1000U Series:
Table of Contents

Advertisement

A.4 b: Application
u

b2: DC Injection Braking

No.
(Addr.
Name
Hex)
b2-01
DC Injection Braking
(0189)
Start Frequency
b2-02
DC Injection Braking
(018A)
Current
b2-03
DC Injection Braking
(018B)
Time at Start
b2-04
DC Injection Braking
(018C)
Time at Stop
b2-09
Motor Pre-Heat Current
(01E1)
2
<1> Default setting is determined by parameter A1-02, Control Method Selection.
u

b3: Speed Search

No.
(Addr
Name
Hex.)
b3-01
Speed Search Selection
(0191)
at Start
b3-03
Speed Search
(0193)
Deceleration Time
V/f Gain during Speed
b3-04
Search (Speed
(0194)
Estimation Type)
b3-05
Speed Search Delay
(0195)
Time
Output Current 1 during
b3-06
Speed Search (Speed
(0196)
Estimation Type)
Output Current 2 during
b3-07
Speed Search (Speed
(0197)
Estimation Type)
Current Control Gain
b3-08
during Speed Search
(198)
(Speed Estimation
Type)
Current Control Integral
b3-09
Time during Speed
(0199)
Search (Speed
Estimation Type)
Speed Search Detection
b3-10
Compensation Gain
(019A)
(Speed Estimation
Type)
Speed Search Method
b3-11
Switching Level (Speed
(19B)
Estimation Type)
196
LCD Display
Sets the frequency at which DC Injection Braking starts when
"Ramp to stop" (b1-03 = 0) is selected.
DCInj Start Freq
Sets the DC Injection Braking current as a percentage of the
DCInj Current
drive rated current.
Sets DC Injection Braking time at start. Disabled when set to
DCInj Time@Start
0.00 seconds.
Sets DC Injection Braking time at stop.
DCInj Time@Stop
Determines the percentage of motor rated output current used
Preheat Current
for the motor pre-heat function.
LCD Display
SpdSrch at Start
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Sets output frequency reduction time during Speed Search.
SpdSrch Dec Time
Determines how much to lower the V/f ratio during Speed
Search.
SpdSrch V/f
Output voltage during Speed Search equals the V/f setting
multiplied by b3-04.
When using an external contactor on the output side, b3-05
Search Delay
delays executing Speed Search after a momentary power loss to
allow time for the contactor to close.
Sets the current injected to the motor at the beginning of Speed
Estimation Speed Search. Set as a coefficient for the motor rated
Srch Im Lvl1
current.
Sets the amount of output current during Speed Estimation
Speed Search as a coefficient for the no-load current (output
current during Speed Search is automatically limited by the
Srch Im Lvl2
drive rated current).
Increase this setting value in increments of 0.1 if the drive fails
to perform Speed Estimation.
Sets the proportional gain for the current controller during
Speed Search.
Srch ACR P Gain
Sets the Integral Time for the current controller during Speed
Search.
Srch ACR I Time
Sets the gain which is applied to the speed detected by Speed
Estimation Speed Search before the motor is reaccelerated.
Srch Detect Comp
Increase this setting if ov occurs when performing Speed Search
after a relatively long period of baseblock.
Uses the amount of voltage remaining in the motor to
automatically switch the search method within the type of speed
Srch Mthd Sw Lvl
measurement.
(200 V class at 100% = 200 V;
400 V class at 100% = 400 V)
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
Description
Description
Values
Page
<1>
Default:
22
Min.: 0.0 Hz
Max.: 10.0 Hz
Default: 50%
Min.: 0
22
Max.: 100
Default: 0.00 s
Min.: 0.00
22
Max.: 10.00
Default: 0.00 s
Min.: 0.00
22
Max.: 10.00
Default: 5%
Min.: 0
22
Max.: 100
Values
Page
Default: 0
25
Range: 0, 1
Default: 2.0 s
Min.: 0.1
25
Max.: 10.0
<1>
Default:
25
Min.: 10%
Max.: 100%
Default: 0.2 s
Min.: 0.0
25
Max.: 100.0
<1>
Default:
25
Min.: 0.0
Max.: 2.0
Default: 1.0
Min.: 0.0
25
Max.: 5.0
<1> <2>
Default:
26
Min.: 0.00
Max.: 6.00
<2>
Default:
26
Min.: 0.0 ms
Max.: 1000.0 ms
Default: 1.05
Min.: 1.00
26
Max.: 1.20
Default: 5.0%
Min.: 0.5
26
Max.: 100.0