u

S4: Bypass Operation

No.
(Addr.
Name
Hex)
S4-01
(322B) BP Auto Transfer on
Fault Enable
S4-02
(322C) Secondary PI User
Display
S4-03
(322D) BP Energy Save Bypass
Timer
S4-04
BP Energy Save Bypass
(322E)
Speed Increase
u

S5: HOA Keypad Parameters

No.
(Addr.
Name
Hex)
S5-01
HAND Frequency
(322F)
Reference Selection
S5-02
HAND/AUTO During
(3230)
Run Selection
S5-03
HAND Mode PI
(3231)
Selection
S5-04
HAND Mode Behavior
(3232)
Selection
S5-05
HAND Frequency
(3233)
Reference 1
HAND Key Function
S5-07
Selection (HOA
(3235)
Keypad)
u

S6: Z1000U Protection

No.
(Addr.
Name
Hex)
S6-01
Emergency Override
(3236)
Speed
S6-02
Emergency Override
(3237)
Reference Selection
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
LCD Display
0: No transfer after fault
BP Fault Trnsfer
1: Transfer to bypass after fault
0: Disabled
1: Enabled
Delta used to determine when to switch into Energy Save Bypass.
BP Enrgy Sav Lvl
This allows for lower frequency output values to also trigger
Energy Save Bypass functionality.
Sets the time in seconds that the drive should run at the specified
speed before entering Energy Save Bypass mode.
BP Enrgy Sav TMR
Sets the value in Hz that the drive will increase the output
frequency above E1-04 before performing an Energy Save
BP Enrgy Sav Inc
transfer to bypass.
LCD Display
HAND Fref Source
0: HOA keypad
0: Operator
1: Terminals
1: Terminals
2: d1-16
2: d1-16
3: S5-05
3: S5-05
4: Determined by b1-01
4: Set by b1-01
HAND/AUTO
0: Disabled
@Run
1: Enabled
0: Disabled
1: Enabled
0: Disabled
HAND Mode PI Sel
1: Enabled
0: Disabled
1: Enabled
0: Legacy operation mode
HAND BehaviorSel
1: Normal operation mode
0: Legacy
2: Normal with memory
1: Normal
2: Normal w/
Note:
Memory
Sets the frequency reference used in HAND mode when S5-01 is
set to 2.
HAND Freq Ref 2
Determines whether the HAND key on the HOA keypad will be
Oper HAND Key
enabled for switching between HAND and AUTO.
0: Disabled
0: Disabled
1: Enabled
1: Enabled
LCD Display
Sets the speed command used in Emergency Override mode when
S6-02 = 0.
E Override Speed
Selects the frequency reference source for the Emergency
E OverrideRefSel
Override function (H1-oo= AF or B0).
0: Use S6-01 Ref
0: Use S6-01 Reference
1: Use AUTO Ref
1: Use AUTO Reference
Description
Description
The drive will always be in AUTO mode at power
up with S5-04 = 1.
Description
A.13 S: Special Application
Values
Page
Default: 1
Range: 0, 1
Default: 0 Hz
Min.: 0
Max.: 20
Default: 60 s
Min.: 10
Max.: 60000
Default: 6 Hz
Min.: 0
Max.: 10
Values
Page
Default: 0
Range: 0 to 4
Default: 1
Range: 0, 1
Default: 1
Range: 0, 1
Default: 1
Range: 0 to 2
Default: 0.00
Hz
Min.: 0.00
Max.: E1-04
Default: 1
Range: 0, 1
Values
Page
Default: 0.00
Hz
Min.: 0.00
Max.: E1-04
Default: 0
Range: 0, 1
155
155
156
156
156
156
156
156
158
158
159
159
A