No.
(Addr.
Name
Hex)
F7-10
(03EE)
Gateway Address 2
<6>
F7-11
(03EF)
Gateway Address 3
<6>
F7-12
(03E0)
Gateway Address 4
<6>
F7-13
Address Mode at Startup
(03F1)
F7-14
Duplex Mode Selection
(03F2)
F7-15
Communication Speed
(03F3)
Selection
<7>
F7-16
Communication Loss
(03F4)
Timeout
F7-17
EtherNet/IP Speed
(03F5)
Scaling Factor
F7-18
EtherNet/IP Current
(03F6)
Scaling Factor
F7-19
EtherNet/IP Torque
(03F7)
Scaling Factor
F7-20
EtherNet/IP Power
(03F8)
Scaling Factor
F7-21
EtherNet/IP Voltage
(03F9)
Scaling Factor
F7-22
EtherNet/IP Time
(03FA)
Scaling
F7-23 to
F7-32
Dynamic Output
(03FB to
Assembly Parameters
0374)
F7-33 to
F7-42
Dynamic Input
(0375 to
Assembly Parameters
037E)
<1> When using this setting, be sure to take safety measures, such as installing an emergency stop switch. The drive will continue to operate when a
fault is detected.
<2> Values shown are for the MECHATROLINK-II option (SI-T3). Values for MECHATROLINK-III option (SI-ET3) are:
Min: 03
Max.: EF
<3> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Cycle power for setting changes to take effect.
<5> When setting F7-13 to 0, all IP addresses (F7-01 to F7-04) must be unique.
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
LCD Display
Sets the second most significant octet of network Gateway
Gateway IP Add 2
address.
Sets the third most significant octet of network Gateway
Gateway IP Add 3
address.
Sets the fourth most significant octet of network Gateway
Gateway IP Add 4
address.
Select the option address setting method
IP Add Mode Sel
0: User Defined
0: Static
1: BOOTP
1: BOOTP
2: DHCP
2: DHCP
Selects duplex mode setting.
Duplex Select
0: Half/Half
0: Half duplex forced
1: Auto/Auto
1: Auto-negotiate duplex mode and communication speed
2: Full/Full
2: Full duplex forced
Baud Rate
Sets the communication speed
10: 10/10 Mbps
10: 10 Mbps
100: 100/100 Mbps
100: 100 Mbps
Sets the timeout value in tenths of a second for communication
loss detection.
CommLoss Tout
Example: Setting this parameter to 100 represents 10.0 seconds.
Setting this parameter to 0 disables the connection timeout.
Sets the scaling factor for the speed monitor in EtherNet/IP
EN Speed Scale
Class ID 2AH Object.
Sets the scaling factor for the output current monitor in
EN Current Scale
EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the torque monitor in EtherNet/IP
EN Torque Scale
Class ID 2AH Object.
Sets the scaling factor for the power monitor in EtherNet/IP
EN Power Scale
Class ID 2AH Object.
Sets the scaling factor for the voltage monitor in EtherNet/IP
EN Voltage Scale
Class ID 2AH Object.
Sets the scaling factor for the time monitor in EtherNet/IP Class
EN Time Scale
ID 2AH Object.
Parameters used in Output Assembly 116. Each parameter
contains a MEMOBUS/Modbus address. The value received
for Output Assembly 116 will be written to this corresponding
MEMOBUS/Modbus address. A MEMOBUS/Modbus address
value of 0 means that the value received for Output Assembly
116 will not be written to any MEMOBUS/Modbus register.
Parameters used in Input Assembly 166. Each parameter
contains a MEMOBUS/Modbus address. The value sent for
Input Assembly 166 will be read from this corresponding
MEMOBUS/Modbus address. A MEMOBUS/Modbus address
value of 0 means that the value sent for Input Assembly 166 is
not defined by the user, therefore the option default register
value will be returned.
Description
<5> <6>
<7>
<7>
A.8 F: Option Settings
Values
Page
Default: 168
Min.: 0
Max.: 255
Default: 1
Min.: 0
Max.: 255
Default: 1
Min.: 0
Max.: 255
Default: 2
Range: 0 to 2
Default: 1
Range: 0 to 2
Default: 10
Range: 10, 100
Default: 0.0 s
Min.: 0.0
Max.: 30.0
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Default: 0