2.5 Drive Cooling Fans
Push the connectors together so
no space remains between them.
A –Opening
2.
Install the cooling fan unit and place the cable back into position.
Note:
1. Replace the whole unit when performing maintenance on the cooling fans.
2. Install the cooling fan unit while pulling the cable upward so that the cable does not get pinched between parts.
A – Pull the cable upwards
B – Bend 3 times
3.
Thread the 4 fan unit screws into the proper holes approximately 2/3 of the way. Leave enough space to reinsert the
fan guard.
A –Screw locations
184
Figure 2.29 Attach the Relay Connector
□
□
□
2
0248, 4
0216, 4
0240
Figure 2.30 Cooling Fan Unit
Figure 2.31 Install the Cooling Fan
Figure 2.32 Attach the Cooling Fan Unit
□
□
4
0302 to 4
0414
A
C – Hook
A
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
A
B
C