O: Operator Related Settings - YASKAWA E1000 Technical Manual

For fan and pump
Table of Contents

Advertisement

B.3 Parameter Table
No. (Addr.)
Name
n8-51
Acceleration/Deceleration Pull-In
(53EH)
Current
n8-54
Voltage Error Compensation Time
(56DH)
Constant
n8-55
Load Inertia
(56EH)
n8-62
(57DH)
Output Voltage Limit
<18>
n8-65
Speed Feedback Detection Control
(65CH)
Gain during ov Suppression
<14> Default setting value is dependent on the motor code set to E5-01.
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.

◆ o: Operator Related Settings

The o parameters are used to set up the digital operator displays.
o1: Digital Operator Display Selection
No. (Addr.)
Name
o1-01
(500H)
Drive Mode Unit Monitor
Selection
o1-02
(501H)
User Monitor Selection after
Power Up
o1-03
Digital Operator Display Selection
(502H)
o1-05
(504H)
LCD Contrast Control
o1-06
User Monitor Selection Mode
(517H)
o1-07
Second Line Monitor Selection
(518H)
o1-08
Third Line Monitor Selection
(519H)
o1-10
User-Set Display Units Maximum
(520H)
Value
o1-11
User-Set Display Units Decimal
(521H)
Display
<10> Default setting is determined by the control mode (A1-02).
<36> Default setting value is determined by the digital operator display selection (o1-03).
388
V/f
OLV/PM
Sets the d-axis current reference during acceleration/deceleration as a percentage of the motor
rated current. Set to a high value when more starting torque is needed.
V/f
OLV/PM
Adjusts the value when hunting occurs at low speed. If hunting occurs with sudden load
changes, increase n8-54 in increments of 0.1. Reduce this setting if oscillation occurs at start.
V/f
OLV/PM
Sets the ratio between motor and machine inertia.
0: less than 1:10.
1: between 1:10 to 1:30.
2: between 1:30 to 1:50.
3: higher than 1:50.
V/f
OLV/PM
Prevents output voltage saturation. Should be set just below the voltage provided by the input
power supply.
V/f
OLV/PM
Sets the gain used for internal speed feedback detection during ov suppression
All Modes
Selects the content of the last monitor that is shown when scrolling through Drive Mode
display. Enter the last three digits of the monitor parameter number to be displayed: U-.
All Modes
1: Frequency reference (U1-01)
2: Motor direction
3: Output frequency (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)
All Modes
Sets the units the drive should use to display the frequency reference and motor speed monitors.
0: 0.01 Hz units
1: 0.01% units (100% = E1-04)
2: r/min units (calculated using the number of motor poles setting in E2-04, or E5-04)
3: User-selected units (set by o1-10 and o1-11)
All Modes
Sets the brightness of the LCD operator (option).
All Modes
0: 3 Monitor sqeuncial (Displays the next 2 sequencial Monitor)
1: 3 Monitor Selectable: o1-07,-08 selected monitor is shown
All Modes
Selects which monitor will be displayed in the second line.
The monitor parameter number is entered into the spaces provided: U-.
For example, set "403" to display monitor parameter U4-03.
All Modes
Selects which monitor will be displayed in the second line.
The monitor parameter number is entered into the spaces provided: U-.
For example, set "403" to display monitor parameter U4-03.
All Modes
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.
0: No decimal point
1: One decimal point
2: Two decimal points
3: Three decimal points
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Description
Description
Setting
common_
Default: 50%
TMonly
Min: 0%
Max: 200%
common_
Default: 1.00 s
TMonly
Min: 0.00 s
Max: 10.00 s
common_
TMonly
Default: 0
Min: 0
Max: 3
common_
Default: 200.0 V
TMonly
Min: 0.0 V
Max: 230.0 V
Default: 1.50
common_
TMonly
Min: 0.00
Max: 10.00
Setting
Default: 106 (Monitor
common_
TMonly
U1-06)
Min: 105
Max: 825
common_
TMonly
Default: 1
Min: 1
Max: 5
common_
TMonly
Default:
<10>
Min: 0
Max: 3
Default: 3
common_
TMonly
Min: 0
Max: 5
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 102
Min: 101
Max: 825
common_
TMonly
Default: 103
Min: 101
Max: 825
common_
Default:
<36>
TMonly
Min: 1
Max: 60000
Default:
<36>
Min: 0
Max: 3
Page
244
244
244
244
245
Page
246
246
246
247
247
247
247
247
247

Advertisement

Table of Contents
loading