YASKAWA E1000 Technical Manual page 380

For fan and pump
Table of Contents

Advertisement

B.3 Parameter Table
H3-
Function
Setting
17
Motor Thermistor (NTC)
1F
Through Mode
30 to 32
DriveWorksEZ Analog Input 1 to 3
H4: Analog Outputs
No.(Addr.)
Name
H4-01
Multi-Function Analog Output
(41DH)
Terminal FM Monitor Selection
H4-02
(41EH)
Multi-Function Analog Output
Terminal FM Gain
H4-03
(41FH)
Multi-Function Analog Output
Terminal FM Bias
H4-04
Multi-Function Analog Output
(420H)
Terminal AM Monitor Selection
H4-05
(421H)
Multi-Function Analog Output
Terminal AM Gain
H4-06
(422H)
Multi-Function Analog Output
Terminal AM Bias
Multi-Function Analog Output
H4-07
Terminal FM Signal Level
(423H)
Selection
Multi-Function Analog Output
H4-08
Terminal AM Signal Level
(424H)
Selection
H5: MEMOBUS/Modbus Serial Communication
No.(Addr.)
Name
H5-01
(425H)
Drive Node Address
<32>
H5-02
Communication Speed Selection
(426H)
H5-03
Communication Parity Selection
(427H)
380
H3 Multi-Function Analog Input Settings
All Modes
10 V = -9°C
0 V = 234°C
Note: This function is available in models CIMR-E4A0930 and 4A1200.
All Modes
Set this value when using the terminal in the pass-through mode.
All Modes
Output is determined by the function selected using DWEZ.
All Modes
Selects the data to be output through multi-function analog output terminal FM.
Set the desired monitor parameter to the digits available in U-. For example, enter "103"
for U1-03.
All Modes
Sets the signal level at terminal FM that is equal to 100% of the selected monitor value.
All Modes
Sets the bias value added to the terminal FM output signal.
All Modes
Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in U-. For example, enter "103"
for U1-03.
All Modes
Sets the signal level at terminal AM that is equal to 100% of the selected monitor value.
All Modes
Sets the bias value added to the terminal AM output signal.
All Modes
0: 0 to 10 V
1: –10 to 10 V
2: 4 to 20 mA
All Modes
0: 0 to 10 V
1: –10 to 10 V
2: 4 to 20 mA
All Modes
Selects drive station node number (address) for MEMOBUS/Modbus terminals R+, R-, S+, S-.
Cycle power for the setting to take effect.
All Modes
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
6: 57600 bps
7: 76800 bps
8: 115200 bps
Cycle power for the setting to take effect.
All Modes
0: No parity
1: Even parity
2: Odd parity
Cycle power for the setting to take effect.
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Description
Description
Description
common_
TMonly
common_
TMonly
common_
TMonly
Setting
common_
TMonly
Default: 102
Min: 000
Max: 999
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
TMonly
Default: 103
Min: 000
Max: 999
Default: 50.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
TMonly
Default: 0
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 1
Setting
common_
Default: 1F
TMonly
Min: 0
Max: FFH
common_
TMonly
Default: 3
Min: 0
Max: 8
common_
TMonly
Default: 0
Min: 0
Max: 2
Page
204
204
204
Page
205
205
205
205
205
205
206
206
Page
416
416
416

Advertisement

Table of Contents
loading

Table of Contents