B.3 Parameter Table
H1-
Function
Setting
90 to 97
DriveWorksEZ Digital Inputs 1 to 8
9F
DriveWorksEZ Disable
■
H2: Multi-Function Digital Outputs
No.(Addr.)
Name
H2-01
Terminals M1-M2 Function
(40BH)
Selection (relays)
H2-02
Terminals M3-M4 Function
(40CH)
Selection (relays)
H2-03
Terminals M5-M6 Function
(40DH)
Selection (relays)
H2-06
Watt Hour Output Unit Selection
(437H)
H2-
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency Reference Source
A
Run Command Source
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
E
Fault
376
H1 Multi-Function Digital Input Selections
All Modes
Reserved for DWEZ input functions
All Modes
Open: DWEZ enabled
Closed: DWEZ disabled
All Modes
Refer to H2 Multi-Function Digital Output Settings on page
values.
All Modes
Outputs a 200 ms pulse signal when the watt-hour counter increases by the units selected.
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
H2 Multi-Function Digital Output Settings
All Modes
Closed: A Run command is active or voltage is output.
All Modes
Open: Output frequency is above the minimum output frequency set in E1-09.
Closed: Output frequency is below the minimum output frequency set in E1-09.
All Modes
Closed: Output frequency equals the speed reference (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output frequency and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output frequency is less than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Output frequency is greater than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Power up is complete and the drive is ready to accept a Run command.
All Modes
Closed: DC bus voltage is below the Uv trip level set in L2-05.
All Modes
Closed: Drive has entered the baseblock state (no output voltage).
All Modes
Open: External Reference 1 or 2 supplies the frequency reference (set in b1-01 or b1-15).
Closed: Digital operator supplies the frequency reference.
All Modes
Open: External Reference 1 or 2 supplies the Run command (set in b1-02 or b1-16).
Closed: Digital operator supplies the Run command.
All Modes
Closed: An overtorque or undertorque situation has been detected.
All Modes
Closed: Analog frequency reference has been lost.
All Modes
Closed: Fault occurred.
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Description
Description
376
for a description of setting
Description
common_
TMonly
common_
TMonly
Setting
Default: 0
Min: 0
Max: 192
common_
Default: 1
TMonly
Min: 0
Max: 192
Default: 2
Min: 0
Max: 192
common_
TMonly
Default: 0
Min: 0
Max: 4
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
Page
190
190
Page
190
190
190
198
Page
190
191
191
191
192
192
193
193
193
193
193
194
194
194