YASKAWA E1000 Technical Manual page 465

For fan and pump
Table of Contents

Advertisement

No.
d2-01
Frequency Reference Upper Limit
d2-02
Frequency Reference Lower Limit
d2-03
Master Speed Reference Lower Limit
d3-01
Jump Frequency 1
d3-02
Jump Frequency 2
d3-03
Jump Frequency 3
d3-04
Jump Frequency Width
d4-01
Frequency Reference Hold Function Selection
d4-10
Up/Down Frequency Reference Limit Selection
d6-01
Field Weakening Level
d6-02
Field Weakening Frequency Limit
d7-01
Offset Frequency 1
d7-02
Offset Frequency 2
d7-03
Offset Frequency 3
E1-01
Input Voltage Setting
E1-03
V/f Pattern Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-07
Middle Output Frequency
E1-08
Middle Output Frequency Voltage
E1-09
Minimum Output Frequency
E1-10
Minimum Output Frequency Voltage
E1-11
Middle Output Frequency 2
E1-12
Middle Output Frequency Voltage 2
E1-13
Base Voltage
E2-01
Motor Rated Current
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-04
Number of Motor Poles
E2-05
Motor Line-to-Line Resistance
E2-10
Motor Iron Loss for Torque Compensation
E2-11
Motor Rated Output
E5-01
Motor Code Selection
E5-02
Motor Rated Power
E5-03
Motor Rated Current
E5-04
Number of Motor Poles
E5-05
Motor Stator Resistance
E5-06
Motor d-Axis Inductance
E5-07
Motor q-Axis Inductance
E5-09
Motor Induction Voltage Constant 1
E5-24
Motor Induction Voltage Constant 2
E5-25
Polarity Judge Selection
F6-01
Communications Error Operation Selection
F6-02
External Fault from Comm. Option Detection Selection
F6-03
External Fault from Comm. Option Operation Selection
F6-04
bUS Error Detection Time
F6-07
NetRef/ComRef Function Selection
F6-08
Reset Communication Parameters
F6-10
CC-Link Node Address
F6-11
CC-Link Communications Speed
F6-14
CC-Link bUS Error Auto Reset
F6-20
MECHATROLINK Station Address
F6-21
MECHATROLINK Frame Size
F6-22
MECHATROLINK Link Speed
F6-23
MECHATROLINK Monitor Selection (E)
F6-24
MECHATROLINK Monitor Selection (F)
F6-25
Operation Selection at Watchdog Timer Error (E5)
F6-26
MECHATROLINK bUS Errors Detected
F6-30
PROFIBUS-DP Node Address
F6-31
PROFIBUS-DP Clear Mode Selection
F6-32
PROFIBUS-DP Data Format Selection
F6-35
CANopen Node ID Selection
F6-36
CANopen Communication Speed
F6-50
DeviceNet MAC Address
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
User
Name
Setting
No.
Name
F6-51
DeviceNet Communication Speed
F6-52
DeviceNet PCA Setting
F6-53
DeviceNet PPA Setting
F6-54
DeviceNet Idle Mode Fault Detection
F6-55
DeviceNet Baud Rate Monitor
F6-56
DeviceNet Speed Scaling
F6-57
DeviceNet Current Scaling
F6-58
DeviceNet Torque Scaling
F6-59
DeviceNet Power Scaling
F6-60
DeviceNet Voltage Scaling
F6-61
DeviceNet Time Scaling
F6-62
DeviceNet Heartbeat Interval
F6-63
DeviceNet Network MAC ID
Multi-Function Digital Input Terminal S1 Function
H1-01
Selection
Multi-Function Digital Input Terminal S2 Function
H1-02
Selection
Multi-Function Digital Input Terminal S3 Function
H1-03
Selection
Multi-Function Digital Input Terminal S4 Function
H1-04
Selection
Multi-Function Digital Input Terminal S5 Function
H1-05
Selection
Multi-Function Digital Input Terminal S6 Function
H1-06
Selection
Multi-Function Digital Input Terminal S7 Function
H1-07
Selection
Multi-Function Digital Input Terminal S8 Function
H1-08
Selection
H2-01
Terminal M1-M2 Function Selection (relay)
H2-02
Terminal M3-M4 Function Selection (photocoupler)
H2-03
Terminal M5-M6 Function Selection (photocoupler)
H2-06
Watt Hour Output Unit Selection
H3-01
Terminal A1 Signal Level Selection
H3-02
Terminal A1 Function Selection
H3-03
Terminal A1 Gain Setting
H3-04
Terminal A1 Bias Setting
H3-05
Terminal A3 Signal Level Selection
H3-06
Terminal A3 Function Selection
H3-07
Terminal A3 Gain Setting
H3-08
Terminal A3 Bias Setting
H3-09
Terminal A2 Signal Level Selection
H3-10
Terminal A2 Function Selection
H3-11
Terminal A2 Gain Setting
H3-12
Terminal A2 Bias Setting
H3-13
Analog Input Filter Time Constant
H3-14
Analog Input Terminal Enable Selection
H3-16
Terminal A1 Offset
H3-17
Terminal A2 Offset
H3-18
Terminal A3 Offset
Multi-Function Analog Output Terminal FM Monitor
H4-01
Selection
H4-02
Multi-Function Analog Output Terminal FM Gain
H4-03
Multi-Function Analog Output Terminal FM Bias
Multi-Function Analog Output Terminal AM Monitor
H4-04
Selection
H4-05
Multi-Function Analog Output Terminal AM Gain
H4-06
Multi-Function Analog Output Terminal AM Bias
Multi-Function Analog Output Terminal FM Signal Level
H4-07
Selection
Multi-Function Analog Output Terminal AM Signal Level
H4-08
Selection
H5-01
Drive Node Address
H5-02
Communication Speed Selection
H5-03
Communication Parity Selection
H5-04
Stopping Method After Communication Error (CE)
H5-05
Communication Fault Detection Selection
H5-06
Drive Transmit Wait Time
E.3 User Setting Table
User
Setting
465
E

Advertisement

Table of Contents
loading