◆ Subchart A-2: Operation with Permanent Magnet Motors

Flowchart A2 in
Figure 4.9
motors can be used for more energy-efficient operation in reduced or variable torque applications.
Figure 4.9
Run the motor without load; check the rotation direction and
operation.Verify external signal commands to the drive work as desired.
<1> Enter the motor code to E5-01 when using a Yaskawa PM motor (SMRA Series, SSR1 Series). If using a motor from another manufacturer,
enter FFFF.
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
describes the set-up procedure for running a PM motor in Open Loop Vector Control. PM
From
Flowchart
A
YES
Motor test report/ data
sheet available?
NO
<1>
Perform PM Stationary
Auto-Tuning (T2-01 = 1)
Connect the load to the motor.
Run the machine and check for desired
operation.
Return to
Flowchart
A
Figure 4.9 Operation with Permanent Magnet Motors
Input the motor data.
<1>
(T2-01 = 0)
YES
Is the motor cable longer
than 50 meters?
NO
4.4 Start-Up Flowcharts
Perform PM Stationary
Auto-Tuning for Stator
Resistance (T2-01 = 2)
4