B.3 Parameter Table
No.(Addr.)
Name
d2-03
Master Speed Reference Lower
(293H)
Limit
d3: Jump Frequency
No.(Addr.)
Name
d3-01
Jump Frequency 1
(294H)
d3-02
Jump Frequency 2
(295H)
d3-03
Jump Frequency 3
(296H)
d3-04
Jump Frequency Width
(297H)
<10> Default setting is determined by the control mode (A1-02).
d4: Frequency Reference Hold and Up/Down 2 Function
No.(Addr.)
Name
d4-01
Frequency Reference Hold
(298H)
Function Selection
d4-10
Up/Down Frequency Reference
(2B6H)
Limit Selection
d6: Field Weakening and Field Forcing
No.(Addr.)
Name
d6-01
Field Weakening Level
(2A0H)
d6-02
Field Weakening Frequency Limit
(2A1H)
d7: Offset Frequency
No.(Addr.)
Name
d7-01
(2B2H)
Offset Frequency 1
d7-02
(2B3H)
Offset Frequency 2
d7-03
(2B4H)
Offset Frequency 3

◆ E: Motor Parameters

E1: V/f Pattern
No.(Addr.)
Name
E1-01
Input Voltage Setting
(300H)
368
All Modes
Sets the lower limit for frequency references from analog inputs as a percentage of the
maximum output frequency.
All Modes
Eliminates problems with resonant vibration of the motor/machine by avoiding continuous
operation in predefined frequency ranges. The drive accelerates and decelerates the motor
through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
All Modes
Sets the dead-band width around each selected prohibited frequency reference point.
All Modes
0: Disabled. Drive starts from zero when the power is switched on.
1: Enabled. At power up, the drive starts the motor at the Hold frequency that was saved.
0: Lower Limit is Determined by d2-02 or Analog Input
1: Lower Limit is Determined by d2-02
V/f
OLV/PM
Sets the drive output voltage for the Field Weakening function as a percentage of the maximum
output voltage.
Enabled when a multi-function input is set for Field Weakening (H1- = 63).
V/f
OLV/PM
Sets the lower limit of the frequency range where Field Weakening control is valid.
The Field Weakening command is valid only at frequencies above this setting and only when
the output frequency matches the frequency reference (speed agree).
All Modes
Added to the frequency reference when the digital input "Frequency offset 1" (H1- = 44) is
switched on.
All Modes
Added to the frequency reference when the digital input "Frequency offset 2" (H1- = 45) is
switched on.
All Modes
Added to the frequency reference when the digital input "Frequency offset 3" (H1- = 46) is
switched on.
All Modes
This parameter must be set to the power supply voltage.
WARNING! Drive input voltage (not motor voltage) must be set in E1-01 for the protective
features of the drive to function properly. Failure to do so may result in equipment damage and/
or death or personal injury.
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Description
Description
Description
Description
Description
Description
Setting
common_
Default: 0.0%
TMonly
Min: 0.0
Max: 110.0%
Setting
common_
TMonly
Default: 0.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz
Default: 1.0 Hz
common_
TMonly
Min: 0.0 Hz
Max: 20.0 Hz
Setting
common_
Default: 0
TMonly
Min: 0
Max: 1
Default: 0
Min: 0
Max: 1
Setting
common_
TMonly
Default: 80%
Min: 0%
Max: 100%
common_
TMonly
Default: 0.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz
Setting
common_
Default: 0.0%
TMonly
Min: -100.0%
Max: 100.0%
common_
Default: 0.0%
TMonly
Min: -100.0%
Max: 100.0%
common_
Default: 0.0%
TMonly
Min: -100.0%
Max: 100%
Setting
common_
TMonly
Default: 200 V
<18>
Min: 155 V
Max: 255 V
Page
167
Page
167
167
167
167
Page
167
168
Page
169
169
Page
169
169
169
Page
170