No-Load Operation Test Run; No-Load Operation Test Run - YASKAWA E1000 Technical Manual

For fan and pump
Table of Contents

Advertisement

4.8 No-Load Operation Test Run

4.8

No-Load Operation Test Run

◆ No-Load Operation Test Run
This section explains how to operate the drive with the motor decoupled from the load during a test run.
Before Starting the Motor
Check the following items before operation:
• Ensure the area around the motor is safe.
• Ensure external emergency stop circuitry is working properly and other safety precautions have been taken.
During Operation
Check the following items during operation:
• The motor should rotate smoothly (i.e., no abnormal noise or oscillation).
• The motor should accelerate and decelerate smoothly.
No-Load Operation Instructions
The following example illustrates a test run procedure using the digital operator.
Note: Before starting the motor, set the frequency reference d1-01 to 6 Hz.
1.
Turn on the power to the drive. The initial display appears.
2.
Press the
key to select LOCAL. The LO/RE light will turn on.
3.
Press
to give the drive a Run command. RUN will light and the motor will rotate at 6 Hz.
4.
Ensure the motor is rotating in the correct direction and that no faults or alarms occur.
If there is no error in step 4, press
5.
increments of 10 Hz, verifying smooth operation at all speeds. For each frequency, check the drive output
current using monitor U1-03. The current should be well below the motor rated current.
6.
The drive should operate normally. Press
complete stop.
120
Step
to increase the frequency reference. Increase the frequency in
STOP
to stop the motor. RUN flashes until the motor comes to a
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Display/Result
ALM
DIGITAL OPERATOR JVOP-182
DRV
REV
DRV
FOUT
DIGITAL OPERATOR JVOP-182
ALM
DRV
REV
DRV
FOUT
LO
ESC
RE
RESET
ENTER
RUN
STOP
Off
On
DIGITAL OPERATOR JVOP-182
ALM
DRV
REV
DRV
FOUT
LO
ESC
RE
RESET
ENTER
RUN
STOP
Off
On
Motor
Forward
ALM
DIGITAL OPERATOR JVOP-182
DRV
REV
DRV
FOUT
LO
ESC
RE
RESET
ENTER
RUN
STOP
Flashing
Off

Advertisement

Table of Contents
loading

Table of Contents