D.3 UL Standards
Model
Terminal
CIMR-E
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4A0515
–, +1
<4>
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4A0675
–, +1
<4>
+3
R/L1, S/L2, T/L3,
R1/L11, S1/L21,
T1/L31
U/T1, V/T2, W/T3
4A0930
<4>
–, +1
+3
R/L1, S/L2, T/L3,
R1/L11, S1/L21,
T1/L31
U/T1, V/T2, W/T3
4A1200
<4>
–, +1
+3
<1> Gauges listed here are for use in Europe and China.
<2> Gauges listed here are for use in the United States.
<3> Gauges listed here are for use in Asia except for China.
<4> Drive models CIMR-E4A0058 to 4A1200 require the use of closed-loop crimp terminals for UL/cUL compliance. Use only the tools
recommended by the terminal manufacturer for crimping.
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a continuous maximum
allowable temperature of 75°C 600 V UL approved vinyl sheathed insulation. Ambient temperature should not exceed 40°C.
Closed-Loop Crimp Terminal Recommendations
Yaskawa recommends using closed-loop crimp terminals on all drive models. UL approval requires the use of UL Listed
crimp terminals when wiring the drive main circuit terminals on models CIMR-E2A0110 to 2A0415 and 4A0058 to
4A1200. Use only crimping tools as specified by the crimp terminal manufacturer. Yaskawa recommends crimp
terminals made by JST and Tokyo DIP (or equivalent) for the insulation cap.
Table D.6
matches the wire gauges and terminal screw sizes with Yaskawa - recommended crimp terminals, tools, and
insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge and screw size
for your drive model. Place orders with a Yaskawa representatives or the Yaskawa sales department.
Wire Gauge (AWG, kcmil)
Model
R/L1, S/L2,
CIMR-E
T/L3
2A0004
2A0006
2A0008
2A0010
14
2A0012
12
<1>
2A0018
2A0021
450
For Europe and China
<1>
Recommended
Applicable
Gauge
Gauge
mm
2
mm
2
120 × 2P
95 to 150
150 × 2P
95 to 150
70 to 150
70 to 150
150
50 to 150
95 × 4P
95 to 150
95 × 4P
95 to 150
70 to 150
70 to 150
95 × 2P
60 to 150
120 × 4P
95 to 150
120 × 4P
95 to 150
95 to 150
95 to 150
120 × 2P
70 to 120
(95 × 4P) × 2
95 to 150
(95 × 4P) × 2
95 to 150
120 to 150
95 to 150
95 × 4P
95 to 120
Table D.6 Closed-Loop Crimp Terminal Size
Screw
U/T1, V/T2,
Size
W/T3
14
<1>
12
M4
10
14
<1>
12
M4
10
14
12
M4
10
<1>
12
M4
10
<1>
For U.S.A.
<2>
Recommended
Applicable
Gauge
Gauge
AWG, kcmil
AWG, kcmil
3/0 × 4P
3/0 to 300
4/0 × 4P
3/0 to 300
1/0 to 300
1/0 to 300
1/0
1/0 to 300
300 × 4P
4/0 to 300
300 × 4P
4/0 to 300
1/0 to 300
1/0 to 300
2/0
2/0 to 300
(4/0 × 4P) × 2
3/0 to 300
(4/0 × 4P) × 2
3/0 to 300
4/0 to 300
4/0 to 300
3/0
3/0 to 250
(300 × 4P) × 2
4/0 to 300
(300 × 4P) × 2
4/0 to 300
250 to 300
4/0 to 300
4/0
4/0 to 250
Tool
Crimp Terminal
Model Number
Machine No.
200 V Class
R2-4
YA-4
R5.5-4
R2-4
YA-4
R5.5-4
R2-4
YA-4
R5.5-4
R5.5-4
YA-4
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
For Asia
<3>
Recommended
Applicable
Gauge
Gauge
mm
2
mm
2
125 × 2P
80 to 150
150 × 2P
80 to 150
60 × 4P
60 to 150
100 × 2P
60 to 150
60
50 to 150
80 × 4P
80 to 150
80 × 4P
80 to 150
125 × 4P
60 to 150
60 × 4P
60 to 150
60
70 to 150
150 × 4P
125 to 150
150 × 4P
125 to 150
(125 × 4P) × 2
100 to 150
125 × 4P
100 to 150
100
80 to 125
(125 × 4P) × 2
100 to 150
(125 × 4P) × 2
100 to 150
(150 × 4P) × 2
125 to 150
(100 × 4P) × 2
100 to 150
125
100 to 125
Insulation Cap
Model No.
Die Jaw
TP-003
AD-900
TP-005
TP-003
AD-900
TP-005
TP-003
AD-900
TP-005
AD-900
TP-005
Tightening
Screw
Torque
Size
Nm (lb.in.)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
Code
<2>
100-054-028
100-054-029
100-054-028
100-054-029
100-054-028
100-054-029
100-054-029

Advertisement