5.3 C: Tuning
Setting a Fixed User Defined Carrier Frequency
A carrier frequency between the fixed selectable values can be entered in parameter C6-03 when C6-02 is set to F. In V/f
Control, parameter C6-04 must also be adjusted to the same value as C6-03.
Setting a Variable Carrier Frequency (V/f Control)
In V/f Control, the carrier frequency can be set up to change linearly with the output frequency. To do this, set the upper
and lower limits for the carrier frequency and the carrier frequency proportional gain (C6-03, C6-04, C6-05) as shown in
Figure
5.22.
Figure 5.22
Note: When C6-05 is set lower than 7, C6-04 is disabled and the carrier frequency will be fixed to the value set in C6-03.
Rated Current Depending on Carrier Frequency
The tables below show the drive output current depending on the carrier frequency settings.
Use the data in
Table 5.13
Three-Phase 200 V Class
Model
CIMR-E
2 kHz
2A0004
3.5
2A0006
6
2A0008
8
2A0010
9.6
2A0012
12
2A0018
17.5
2A0021
21
2A0030
30
2A0040
40
2A0056
56
2A0069
69
2A0081
81
2A0110
110
2A0138
138
Three-Phase 200 V Class
Model
CIMR-E
2 kHz
2A0169
169
2A0211
211
2A0250
250
2A0312
312
2A0360
360
2A0415
415
164
Carrier Frequency
C6-03
C6-04
Figure 5.22 Carrier Frequency Changes Relative to Output Frequency
to linearly calculate output current values for carrier frequencies not listed in the tables.
Table 5.13 Carrier Frequency and Current Derating
Rated Current (A)
8 kHz
15 kHz
3.2
5
6.9
8
11
14
17.5
25
33
47
60
75
85
115
Rated Current (A)
5 kHz
10 kHz
145
180
215
283
346
415
Output
x C6-05
Frequency
Output Frequency
E1-04
Max Output Frequency
Model
CIMR-E
2.56
4A0002
4
4A0004
5.5
4A0005
6.4
4A0007
8.8
4A0009
11.2
4A0011
14
4A0018
20
4A0023
26.4
4A0031
37.6
4A0038
48
4A0044
53
4A0058
60
4A0072
81
4A0088
4A0103
Model
CIMR-E
116
4A0139
144
4A0165
172
4A0208
226
4A0250
277
4A0296
332
4A0362
4A0414
4A0515
4A0675
4A0930
4A1200
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
common_TMonly
Three-Phase 400 V Class
Rated Current (A)
2 kHz
8 kHz
2.1
1.8
4.1
3.4
5.4
4.8
6.9
5.5
8.8
7.2
11.1
9.2
17.5
14.8
23
18
31
24
38
31
44
39
58
45
72
60
88
75
103
91
Three-Phase 400 V Class
Rated Current (A)
2 kHz
5 kHz
139
112
165
150
208
180
250
216
296
260
362
304
414
370
515
397
675
528
930
716
1200
938
15 kHz
1.1
2
2.9
3.3
4.3
5.5
8.9
10.8
14.4
18.6
23.4
27
36
45
55
10 kHz
78
105
126
151
182
213

Advertisement