YASKAWA E1000 Technical Manual page 372

For fan and pump
Table of Contents

Advertisement

B.3 Parameter Table
No.(Addr.)
Name
F6-30
PROFIBUS-DP Node Address
(3CBH)
F6-31
PROFIBUS-DP Clear Mode
(3CCH)
Selection
F6-32
PROFIBUS-DP Data Format
(3CDH)
Selection
F6-35
CANopen Node ID Selection
(3D0H)
F6-36
CANopen Communication Speed
(3D1H)
F6-50
DeviceNet MAC Address
(3C1H)
F6-51
DeviceNet Communication Speed
(3C2H)
F6-52
DeviceNet PCA Setting
(3C3H)
F6-53
DeviceNet PPA Setting
(3C4H)
F6-54
DeviceNet Idle Mode Fault
(3C5H)
Detection
F6-55
DeviceNet Baud Rate Monitor
(3C6H)
F6-56
DeviceNet Speed Scaling
(3D7H)
F6-57
DeviceNet Current Scaling
(3D8H)
F6-58
DeviceNet Torque Scaling
(3D9H)
F6-59
DeviceNet Power Scaling
(3DAH)
F6-60
DeviceNet Voltage Scaling
(3DBH)
F6-61
DeviceNet Time Scaling
(3DCH)
F6-62
DeviceNet Heartbeat Interval
(3DDH)
F6-63
DeviceNet Network MAC ID
(3DEH)
F6-64 to
F6-71
Reserved
(3DFH to
3C8H)
<3> Parameter setting value is not reset to the default value when the drive is initialized.
372
All Modes
Sets the node address.
All Modes
0: Resets drive operation with a Clear mode command.
1: Maintains the previous operation state when Clear mode command is given.
All Modes
0: PPO Type
1: Conventional
All Modes
Sets the node address.
All Modes
0: Auto-detection
1: 10 kbps
2: 20 kbps
3: 50 kbps
4: 125 kbps
5: 250 kbps
6: 500 kbps
7: 800 kbps
8: 1 Mbps
All Modes
Selects the drives MAC address.
All Modes
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from network
4: Detect automatically
All Modes
Sets the format of the data set from the DeviceNet master to the drive.
All Modes
Sets the format of the data set from the drive to the DeviceNet master.
All Modes
0: Enabled
1: Disabled, no fault detection
All Modes
Used to verify the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
All Modes
Sets the scaling factor for the speed monitor in DeviceNet.
All Modes
Sets the scaling factor for the output current monitor in DeviceNet.
All Modes
Sets the scaling factor for the torque monitor in DeviceNet.
All Modes
Sets the scaling factor for the power monitor in DeviceNet.
All Modes
Sets the scaling factor for the voltage monitor in DeviceNet.
All Modes
Sets the scaling factor for the time monitor in DeviceNet.
All Modes
Sets the heartbeat interval for DeviceNet communications.
All Modes
Used to verify the MAC ID the drive has been assigned.
All Modes
Reserved for Dynamic I/O Assembly Parameters.
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Description
Setting
common_
Default: 0
TMonly
Min: 0
Max: 125
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 126
common_
TMonly
Default: 6
Min: 0
Max: 8
Default: 0
common_
TMonly
Min: 0
Max: 64
common_
TMonly
Default: 0
Min: 0
Max: 4
Default: 21
common_
TMonly
Min: 0
Max: 255
Default: 71
common_
TMonly
Min: 0
Max: 255
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 2
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
common_
Default: 0
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: 0
Max: 10
Default: 0
common_
TMonly
Min: 0
Max: 63
common_
TMonly
Page

Advertisement

Table of Contents
loading

Table of Contents