YASKAWA E1000 Technical Manual page 157

For fan and pump
Table of Contents

Advertisement

11: Mtr (Meters)
12: Ft (Feet)
13: LPN (Liters/min)
14: CMM (Cubic M/min)
b5-42: PI Output Monitor Calculation Method
No.
b5-42
0: Linear unit
1: Square root unit
2: Quadratic unit
3: Cubic unit
XXXXYY.YY
b5-43: upper 4 digits (XXXX)
b5-44: lower 4 digits (YYYY)
b5-43/b5-44: Custom PI Output Monitor Setting 1/2
U5-14 and U5-15 show Custom PI output. U5-14 shows the upper 4 digits and U5-15 shows the lower 4 digits.
It shows 999999.99 maximum. b5-43 and b5-44 is used for setting maximum monitor value at maximum frequency.
No.
b5-43
b5-44
b5-45: Custom PI Output Monitor Setting 3
b5-14 shows Custom PI Output. b5-45 is used for setting the minimum display value at 0 speed. This function is effective
when b5-42 is set to 0 (Linear unit).
No.
b5-45
b5-46: PI Setpoint Monitor Unit Selection
Sets the Operator display units in U5-01 and U5-04 when b5-20
No.
b5-46
0: WC (Inch of Water)
1: PSI (ib/Sq inch)
2: GPM (Gallons/min)
3: F (Deg Fahrenheit)
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
Name
PI Output Monitor Calculation Method
U5-07
U5-08
b5-42
1:Square root
b5-45 (ZZZ.Z)
0
Name
Custom PI Output Monitor Setting 1
Custom PI Output Monitor Setting 2
Name
Custom PI output monitor setting 3
Name
PI Setpoint Value Monitor Unit Selection
0:Linear
2:Quadratic
3:Cubic
3.
=
5.2 b: Application
Setting Range
Default
0 to 3
common_TMonly
PI Output
F m ax
Setting Range
Default
0 to 9999
0.00 to 99.99
Setting Range
Default
0.0 to 999.9
Setting Range
Default
0 to 14
0
0
0.00
5
0.0
0
157