YASKAWA E1000 Technical Manual page 316

For fan and pump
Table of Contents

Advertisement

7.4 Cooling Fan and Circulation Fan
5.
Remove the fan guard and circulation fan casing. Replace the cooling fans.
Figure 7.28
Cooling Fan Wiring
1.
Position the protective tube so that the fan connector sits in the center of the protective tube.
2.
Place the fan connector covered by the tube as shown in the drawings below.
Figure 7.29
Cooling Fan B1
3.
Double check the relay connector to ensure that it is properly connected.
316
E
D
C
A – Fan Guard
B – Cooling Fan
C – Fan Unit Case
Figure 7.28 Fan Unit Disassembly: 4A0414
Protective tube
Cooling Fan B2 Cooling Fan B3
Figure 7.29 Cooling Fan Wiring: 4A0414
D – Circulation Fan Base
E – Circulation Fan
YEC_TMon
ly
Connector
Connector
for fan B1
for fan B2
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual