B: Application - YASKAWA E1000 Technical Manual

For fan and pump
Table of Contents

Advertisement

◆ b: Application

Application parameters configure the source of the Run command, DC Injection Braking, Speed Search, timer functions,
PI control, the Dwell function, Energy Savings, and a variety of other application-related settings.
b1: Operation Mode Selection
No.(Addr.)
Name
b1-01
Frequency Reference Selection 1
(180H)
b1-02
Run Command Selection 1
(181H)
b1-03
Stopping Method Selection
(182H)
b1-04
Reverse Operation Selection
(183H)
b1-06
Digital Input Reading
(185H)
b1-07
LOCAL/REMOTE Run Selection
(186H)
b1-08
Run Command Selection While in
(187H)
Programming Mode
b1-11
Drive Delay Time Setting
(1DFH)
b1-14
Phase Order Selection
(1C3H)
b1-15
Frequency Reference Selection 2
(1C4H)
b1-16
Run Command Selection 2
(1C5H)
b1-17
Run Command at Power Up
(1C6H)
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
All Modes
0: Operator Keypad
1: Analog Input Terminals
2: MEMOBUS/Modbus Communications
3: Option Card
4: Pulse Train Input
All Modes
0: Operator
1: Control Circuit Terminal
2: MEMOBUS/Modbus Communications
3: Option Card
All Modes
0: Ramp to Stop
1: Coast to Stop
2: DC Injection Braking to Stop
3: Coast to Stop with Timer
All Modes
0: Reverse Operation Enabled.
1: Reverse Operation Disabled.
All Modes
0: Read Once
1: Read Twice
All Modes
0: Run Command must be cycled
1: Accept Run Command at the new source
All Modes
0: Disabled
1: Enabled
2: Prohibit entering Programing During Run.
All Modes
The Drive will delay executing any run command until the b1-11 time has expired.
All Modes
0: Standard Phase Order
1: Switched phase order (reverses the direction of the motor)
All Modes
Enabled when an input terminal set for "External Reference 1/2 Selection" (H1- = 2)
closes.
0: Operator Keypad
1: Analog Input Terminals
2: MEMOBUS/Modbus Communications
3: Option Card
4: Pulse Train Input
All Modes
Enabled when a terminal set for "External Reference 1/2 Selection" (H1- = 2) closes.
0: Operator Keypad
1: Analog Input Terminals
2: MEMOBUS/Modbus Communications
3: Option Card
4: Pulse Train Input
All Modes
0: Run Command at Power Up is Not Issued
1: Run Command at Power Up is Issued
Description
B.3 Parameter Table
Setting
Page
common_
TMonly
Default: 1
Min: 0
Max: 4
common_
TMonly
Default: 1
Min: 0
Max: 3
common_
TMonly
Default: 0
Min: 0
Max: 3
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 1
TMonly
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 2
common_
Default: 0 s
TMonly
Min: 0 s
Max: 600 s
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 4
common_
TMonly
Default: 0
Min: 0
Max: 4
common_
Default: 0
TMonly
Min: 0
Max: 1
131
132
133
135
135
135
136
136
136
137
137
137
B
361

Advertisement

Table of Contents
loading

Table of Contents