YASKAWA E1000 Technical Manual page 365

For fan and pump
Table of Contents

Advertisement

No.(Addr.)
Name
b5-39
PI Setpoint Display Digits
(1FFH)
b5-40
Frequency Reference Monitor
(17FH)
Content During PI
b5-41
PI Unit Selection
(160H)
b5-42
(161H)
PI Output Monitor Calculation
Method
b5-43
(162H)
Custom PI Output Monitor
Setting 1
b5-44
(163H)
Custom PI Output Monitor
Setting 2
b5-45
(164H)
Custom PI Output Monitor
Setting 3
b5-46
PI Setpoint Monitor Unit Selection
(165H)
b5-47
Reverse Operation Selection 2 by
(17DH)
PI Output
<5> Default setting is dependent on PI setpoint scaling (b5-20).
b8: Energy Saving
No.(Addr.)
Name
b8-01
Energy Saving Control Selection
(1CCH)
b8-04
Energy Saving Coefficient Value
(1CFH)
b8-05
Power Detection Filter Time
(1D0H)
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
All Modes
0: No decimal places
1: One decimal places
2: Two decimal places
3: Three decimal places
All Modes
0: Frequency Reference (U1-01) After PI
1: Frequency Reference (U1-01)
All Modes
0: WC (Inch of Water)
1: PSI (ib/Sq inch)
2: GPM (Gallons/min)
3: F (Deg Fahrenheit)
4: CFM (Cubic ft/min)
5: CMH (Cubic M/h)
6: LPH (Liters/h)
7: LPS (Liters/s)
8: Bar (Bar)
9: Pa (Pascals)
10: C (Deg Celsius)
11: Mtr (Meters)
12: Ft (Feet)
13: LPN (Liters/min)
14: CMM (Cubic M/min)
All Modes
0: Linear unit
1: Square root unit
2: Quadratic unit
3: Cubic unit
All Modes
U5-14, U5-15 show Custom PI output. U5-14 shows the upper 4digits and U5-15 shows the
lower 4 digits.
It shows 999999.99 maximum. b5-43 and b5-44 is used for setting maximum monitor value at
maximum frequency.
All Modes
b5-07,-08 show Custom PI output.b5-45 is used for setting the minimum display value at o
speed. This function can be effective when b5-42 is set to 1 (Linear unit)
All Modes
0: WC (Inch of Water)
1: PSI (ib/Sq inch)
2: GPM (Gallons/min)
3: F (Deg Fahrenheit)
4: CFM (Cubic ft/min)
5: CMH (Cubic M/h)
6: LPH (Liters/h)
7: LPS (Liters/s)
8: Bar (Bar)
9: Pa (Pascals)
10: C (Deg Celsius)
11: Mtr (Meters)
12: Ft (Feet)
13: LPN (Liters/min)
14: CMM (Cubic M/min)
All Modes
Reverse operation selection when b5-01 = 3 or 4.
0: Zero limit when PI output is a negative value.
1:Reverse operation when PI output is a negative value
(Zero limit if the reverse operation is prohibited by b1-04).
V/f
OLV/PM
0: Disabled
1: Enabled
V/f
OLV/PM
Determines the level of maximum motor efficiency. Setting range is 0.0 to 2000.0 maximum
output up to 3.7 kW. Refer to
Model Number and Nameplate Check on page
V/f
OLV/PM
Sets a time constant filter for output power detection.
Description
Description
29.
B.3 Parameter Table
Setting
Page
common_
TMonly
Default:
<5>
Min: 0
155
Max: 3
common_
Default: 0
TMonly
Min: 0
155
Max: 1
common_
TMonly
Default: 0
Min: 0
156
Max: 14
common_
TMonly
Default: 0
Min: 0
157
Max: 3
Default: 0
common_
Min: 0
157
TMonly
Max: 9999
Default: 0.00
Min: 0.00
157
Max: 99.99
common_
Default: 0.0
TMonly
Min: 0.0
157
Max: 999.9
common_
TMonly
Default: 0
Min: 0
157
Max: 14
common_
TMonly
Default: 1
Min: 0
158
Max: 1
Setting
Page
common_
Default:
<10>
TMonly
Min: 0
158
Max: 1
common_
Default:
<8> <9>
TMonly
Min: 0.00
158
Max: 655.00
Default: 20 ms
common_
TMonly
Min: 0 ms
159
Max: 2000 ms
B
365