8-4-4

Parameter Write Mode

The following operation must be performed so that set values changed in Parameter Setting Mode are
saved to EEPROM.
1
Save the changed setting to memory.
Key
operation
2
Return to the parameter write mode display.
Key
operation
Precautions for Correct Use
Precautions for Correct Use
• Write the data again if a write alarm occurs. If a write alarm persists, the Servo Drive may be
faulty.
• Do not turn OFF the power supply while the Servo Drive is writing to the EEPROM. If the
power supply is cut off, incorrect data may be written. In case that this happens, set all the
parameters again and retry writing the data.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Display example
Press
Press
Press and hold
The number of dashes on the display increases.
The parameter write process starts. (This display appears only
momentarily.)
This indicates a normal completion. Other than this, the follwing displays
may be shown
the changed parameters are enabled only after the system is restarted.
Turn OFF and then ON the power supply again.
Display example
Press
Description
key to switch to the parameter write mode display.
key to switch to the parameter write mode display.
key for 5 seconds or more (until
and
also indicates a normal completion, but it means that some of
indicates a write alarm. Write the data again.
Description
key to return to the parameter write mode display.
8 Operation
appears).
.
8 - 21