Omron G5 Series User Manual page 355

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

Pn205
Notch 2 Width Setting
Setting
0 to 20
range
• Select the notch width of the second resonance suppression notch filter.
• Increasing the setting value widens the notch width. Normally, use the default set value.
Pn206
Notch 2 Depth Setting
Setting
0 to 99
range
• Set the notch depth of the second resonance suppression notch filter.
• Increasing the setting value shortens the notch depth and the phase lag.
Pn207
Notch 3 Frequency Setting
Setting
50 to 5,000
range
• Set the notch frequency of the third resonance suppression notch filter.
• When set to 5,000, the notch filter function is disabled.
Pn208
Notch 3 Width Setting
Setting
0 to 20
range
• Select the notch width of the third resonance suppression notch filter.
• Increasing the setting value widens the notch width. Normally, use the default set value.
Pn209
Notch 3 Depth Setting
Setting
0 to 99
range
• Set the notch depth of the third resonance suppression notch filter.
• Increasing the setting value shortens the notch depth and the phase lag.
Pn210
Notch 4 Frequency Setting
Setting
50 to 5,000
range
• Set the notch frequency of the fourth resonance suppression notch filter.
• When set to 5,000, the notch filter function is disabled.
Pn211
Notch 4 Width Setting
Setting
0 to 20
range
• Select the notch width of the fourth resonance suppression notch filter.
• Increasing the setting value widens the notch width. Normally, use the default set value.
Pn212
Notch 4 Depth Setting
Setting
0 to 99
range
• Set the notch depth of the fourth resonance suppression notch filter.
• Increasing the setting value shortens the notch depth and the phase lag.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Unit
Unit
Unit
Hz
Unit
Unit
Unit
Hz
Unit
Unit
7 Parameter Details
Default
2
Cycle the
setting
power supply
Default
0
Cycle the
setting
power supply
Default
5,000
Cycle the
setting
power supply
Default
2
Cycle the
setting
power supply
Default
0
Cycle the
setting
power supply
Default
5,000
Cycle the
setting
power supply
Default
2
Cycle the
setting
power supply
Default
0
Cycle the
setting
power supply
All
All
All
All
All
7
All
All
All
7 - 21